HIGH-PERFORMANCE MEMBRANE CHROMATOGRAPHY OF SERUM AND PLASMA-MEMBRANE PROTEINS

被引:113
作者
JOSIC, D [1 ]
REUSCH, J [1 ]
LOSTER, K [1 ]
BAUM, O [1 ]
REUTTER, W [1 ]
机构
[1] FREE UNIV BERLIN,INST MOLEK BIOL & BIOCHEM,W-1000 BERLIN 33,GERMANY
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 590卷 / 01期
关键词
D O I
10.1016/0021-9673(92)87006-T
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Porous discs made of poly(glycidyl methacrylate) were used for high-performance membrane chromatography (HPMC) of proteins. In model experiments, separations of standard proteins by anion-exchange HPMC using a DEAE disc were carried out. The influences of sample distribution and disc diameter and thickness on separation performance were studied. The separation disc allowed a scaling-up from analytical (diameter 10 mm) to semi-preparative (diameter 50 mm) dimensions. In an application study, separations with anion-exchange and affinity HPMC were carried out using different complex samples such as rat serum and plasma membrane proteins. In all experiments the results on poly(glycidyl methacrylate) discs were comparable to those achieved on adequate high-performance liquid chromatographic (HPLC) columns. However, the separations on HPMC discs could be carried out faster than corresponding separations on HPLC columns. The pressure drop on the discs was low even at high flow-rates. The experiments show that the poly(glycidyl methacrylate) discs used are especially suitable for the isolation of proteins and other biopolymers which occur in a diluted state in complex mixtures.
引用
收藏
页码:59 / 76
页数:18
相关论文
共 18 条
[1]   CARRIER MEMBRANE AS A STATIONARY PHASE FOR AFFINITY-CHROMATOGRAPHY AND KINETIC-STUDIES OF MEMBRANE-BOUND ENZYMES [J].
ABOUREBYEH, H ;
KORBER, F ;
SCHUBERTREHBERG, K ;
REUSCH, J ;
JOSIC, D .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 566 (02) :341-350
[2]   MICROFILTRATION MEMBRANES AS PSEUDO-AFFINITY ADSORBENTS - MODIFICATION AND COMPARISON WITH GEL BEADS [J].
CHAMPLUVIER, B ;
KULA, MR .
JOURNAL OF CHROMATOGRAPHY, 1991, 539 (02) :315-325
[3]  
CUMMINGS LJ, 1990, INT LAB, V9, P40
[4]  
ELOVSON J, 1980, J BIOL CHEM, V255, P5807
[5]   ANION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF MEMBRANE-PROTEINS FROM LIVER AND MORRIS HEPATOMAS [J].
JOSIC, D ;
HOFMANN, W ;
WIELAND, B ;
NUCK, R ;
REUTTER, W .
JOURNAL OF CHROMATOGRAPHY, 1986, 359 :315-322
[6]   THE APPLICATION OF IMMOBILIZED AFFINITY LIGANDS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
JOSIC, D ;
REUTTER, W ;
KRAMER, DM .
ANGEWANDTE MAKROMOLEKULARE CHEMIE, 1989, 166 :249-256
[7]   PURIFICATION OF LIVER AND HEPATOMA MEMBRANE-PROTEINS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
JOSIC, D ;
SCHUETT, W ;
NEUMEIER, R ;
REUTTER, W .
FEBS LETTERS, 1985, 185 (01) :182-186
[8]   PREPARATIVE ISOLATION OF GLYCOPROTEINS FROM PLASMA-MEMBRANES OF DIFFERENT RAT ORGANS [J].
JOSIC, D ;
ZEILINGER, K ;
LIM, YP ;
RAPS, M ;
HOFMANN, W ;
REUTTER, W .
JOURNAL OF CHROMATOGRAPHY, 1989, 484 :327-335
[9]   CROWN ETHERS AS LIGANDS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS AND NUCLEIC-ACIDS [J].
JOSIC, D ;
REUTTER, W ;
REUSCH, J .
JOURNAL OF CHROMATOGRAPHY, 1989, 476 :309-318
[10]   CLEAVAGE OF STRUCTURAL PROTEINS DURING ASSEMBLY OF HEAD OF BACTERIOPHAGE-T4 [J].
LAEMMLI, UK .
NATURE, 1970, 227 (5259) :680-+