A METHOD FOR ESTIMATION OF CHLORINATED BIPHENYLS IN SURFACE WATERS - INFLUENCE OF SAMPLING METHOD ON ANALYTICAL RESULTS

被引:46
|
作者
HERMANS, JH [1 ]
SMEDES, F [1 ]
HOFSTRAAT, JW [1 ]
COFINO, WP [1 ]
机构
[1] TIDAL WATERS DIV,POB 207,9750 AE HAREN,NETHERLANDS
关键词
D O I
10.1021/es00034a023
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An accurate extraction and measurement procedure to determine chlorinated biphenyls (CBs) in surface waters was developed, and sampling techniques for removing suspended matter (SPM) were investigated. The procedure involved a 10-L batch liquid-liquid extraction directly from the sample bottle to prevent loss due to adsorption to the wall. Exhaustive extraction for recovery measurements was proposed, next to spikes, resulting in an extraction time of 10-45 h. A detection limit lower than 10 pg/kg and a coefficient of variation of 3-9% were obtained. Two sampling techniques to remove SPM were investigated: filtration and continuous-flow centrifugation. Filter clogging and adsorption affected the accuracy of the filtration technique. Insufficient separation of low-density particulate organic matter in continuous-flow centrifuge determined the CB contents measured in centrifugates. Results using these techniques for distribution or bioavailability studies are questionable because freely dissolved CBs and dissolved organic matter (DOM) bound CBs cannot be distinguished. Centrifugation may be applicable to transport studies.
引用
收藏
页码:2028 / 2035
页数:8
相关论文
共 50 条
  • [21] Influence of Sampling Delay on the Estimation of Lithium-Ion Battery Parameters and an Optimized Estimation Method
    Jiang, Bing
    Chen, Zeqi
    Chen, Feifan
    ENERGIES, 2019, 12 (10)
  • [22] DEVELOPMENT AND USE OF A SAMPLING AND ANALYTICAL METHOD FOR AZODICARBONAMIDE
    AHRENHOLZ, SH
    NEUMEISTER, CE
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1987, 48 (05): : 442 - 446
  • [23] DEVELOPMENT OF A SAMPLING AND ANALYTICAL METHOD FOR THE INSECTICIDE PROPOXUR
    VASTA, JF
    KVARTEK, EJ
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1985, 46 (04): : 230 - 232
  • [24] THE INFLUENCE OF PLASMA SAMPLING TIMES ON ACCURACY OF ESTIMATION OF THE INPUT FUNCTION IN THE DEOXYGLUCOSE METHOD
    JOVKAR, S
    NAKAI, H
    EVANS, A
    DIKSIC, M
    YAMAMOTO, YL
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) : 999 - 1000
  • [25] Influence of friction on sampling disturbance of lunar surface in direct push sampling method based on DEM
    Gao, Xingwen
    Tang, Dewei
    Yue, Honghao
    Jiang, Shengyuan
    Deng, Zongquan
    ADVANCES IN SPACE RESEARCH, 2017, 59 (12) : 3036 - 3044
  • [26] An Analytical Method for Parameter Estimation Errors
    Fan, Qiuhong
    Wei, Qun
    Li, Peng
    Liu, Baoxiang
    INFORMATION COMPUTING AND APPLICATIONS, PT 2, 2012, 308 : 309 - 314
  • [27] A SIMPLE COLORIMETRIC METHOD FOR SULPHATE ESTIMATION IN WATERS
    VINAYAK, CP
    SETH, SP
    HUSAIN, K
    INDIAN JOURNAL OF TECHNOLOGY, 1966, 4 (11): : 344 - &
  • [28] FIELD METHOD FOR ESTIMATION OF URANIUM IN NATURAL WATERS
    HEUNISCH, GW
    MIKROCHIMICA ACTA, 1970, (02) : 258 - &
  • [30] Comparison of sampling and analytical methods for monitoring of cyanobacteria-dominated surface waters
    Ahn, Chi-Yong
    Joung, Seung-Hyun
    Park, Chan-Sun
    Kim, Hee-Sik
    Yoon, Byung-Dae
    Oh, Hee-Mock
    HYDROBIOLOGIA, 2008, 596 (1) : 413 - 421