PRODUCTION OF AND STUDIES WITH SECONDARY RADIOACTIVE ION-BEAMS AT LISE

被引:117
作者
MUELLER, AC [1 ]
ANNE, R [1 ]
机构
[1] GANIL,F-14021 CAEN,FRANCE
关键词
D O I
10.1016/0168-583X(91)96095-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The doubly achromatic spectrometer LISE, installed at GANIL, has delivered secondary radioactive beams for the past 6 years. Essentially, it consists of two dipole magnets selecting (in A/Z) and refocussing (achromatically) the projectile-like fragment beams emitted at 0-degrees. Important features of LISE and selected experimental results will be discussed. LISE was substantially upgraded, recently, by adding a Wien filter, providing secondary radioactive beams of still increased intensity and isotopic purity.
引用
收藏
页码:559 / 563
页数:5
相关论文
共 25 条
[1]   OBSERVATION OF FORWARD NEUTRONS FROM THE BREAK-UP OF THE LI-11 NEUTRON HALO [J].
ANNE, R ;
ARNELL, SE ;
BIMBOT, R ;
EMLING, H ;
GUILLEMAUDMUELLER, D ;
HANSEN, PG ;
JOHANNSEN, L ;
JONSON, B ;
LEWITOWICZ, M ;
MATTSSON, S ;
MUELLER, AC ;
NEUGART, R ;
NYMAN, G ;
POUGHEON, F ;
RICHTER, A ;
RIISAGER, K ;
SAINTLAURENT, MG ;
SCHRIEDER, G ;
SORLIN, O ;
WILHELMSEN, K .
PHYSICS LETTERS B, 1990, 250 (1-2) :19-23
[2]   THE ACHROMATIC SPECTROMETER LISE AT GANIL [J].
ANNE, R ;
BAZIN, D ;
MUELLER, AC ;
JACMART, JC ;
LANGEVIN, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 257 (02) :215-232
[3]  
ANNE R, IN PRESS
[4]  
BIMBOT R, 1985, Z PHYS A, V322, P433
[5]   BETA-DELAYED PROTON DECAY OF THE TZ=-2-5 ISOTOPE 31AR [J].
BORREL, V ;
JACMART, JC ;
POUGHEON, F ;
RICHARD, A ;
ANNE, R ;
BAZIN, D ;
DELAGRANGE, H ;
DETRAZ, C ;
GUILLEMAUDMUELLER, D ;
MUELLER, AC ;
ROECKL, E ;
SAINTLAURENT, MG ;
DUFOUR, JP ;
HUBERT, F ;
PRAVIKOFF, MS .
NUCLEAR PHYSICS A, 1987, 473 (02) :331-341
[6]  
BORREL V, 1983, Z PHYS A, V314, P91
[7]   SEARCH FOR DIRECT 2-PROTON RADIOACTIVITY FROM TI ISOTOPES AT THE PROTON DRIP LINE [J].
DETRAZ, C ;
ANNE, R ;
BRICAULT, P ;
GUILLEMAUDMUELLER, D ;
LEWITOWICZ, M ;
MUELLER, AC ;
ZHANG, YH ;
BORREL, V ;
JACMART, JC ;
POUGHEON, F ;
RICHARD, A ;
BAZIN, D ;
DUFOUR, JP ;
FLEURY, A ;
HUBERT, F ;
PRAVIKOFF, MS .
NUCLEAR PHYSICS A, 1990, 519 (03) :529-547
[8]   PROJECTILE FRAGMENTS ISOTOPIC-SEPARATION - APPLICATION TO THE LISE SPECTROMETER AT GANIL [J].
DUFOUR, JP ;
DELMORAL, R ;
EMMERMANN, H ;
HUBERT, F ;
JEAN, D ;
POINOT, C ;
PRAVIKOFF, MS ;
FLEURY, A ;
DELAGRANGE, H ;
SCHMIDT, KH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 248 (2-3) :267-281
[9]   BETA-DELAYED MULTI-NEUTRON RADIOACTIVITY OF B-17,BE-14,C-19 [J].
DUFOUR, JP ;
DELMORAL, R ;
HUBERT, F ;
JEAN, D ;
PRAVIKOFF, MS ;
FLEURY, A ;
MUELLER, AC ;
SCHMIDT, KH ;
SUMMERER, K ;
HANELT, E ;
FREHAUT, J ;
BEAU, M ;
GIRAUDET, G .
PHYSICS LETTERS B, 1988, 206 (02) :195-198
[10]  
GUILLEMAUDMUELL.D, 1988, AIP C P, V164, P757