ERRORS INTRODUCED BY TISSUE HETEROGENEITY IN ESTIMATION OF LOCAL CEREBRAL GLUCOSE-UTILIZATION WITH CURRENT KINETIC-MODELS OF THE [F-18] FLUORODEOXYGLUCOSE METHOD

被引:72
作者
SCHMIDT, K [1 ]
LUCIGNANI, G [1 ]
MORESCO, RM [1 ]
RIZZO, G [1 ]
GILARDI, MC [1 ]
MESSA, C [1 ]
COLOMBO, F [1 ]
FAZIO, F [1 ]
SOKOLOFF, L [1 ]
机构
[1] UNIV MILAN, INST H SAN RAFFAELE,DEPT MED,CNR, IST NEUROSCI & BIOIMMAGINI, I-20122 MILAN, ITALY
关键词
APPARENT GLUCOSE-6-PHOSPHATASE ACTIVITY; K4-ASTERISK; MODELING; RATE CONSTANT ESTIMATION; RATE CONSTANTS;
D O I
10.1038/jcbfm.1992.114
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The effects of tissue heterogeneity on the estimation of regional cerebral glucose utilization (rCMR(glc)) in normal humans with [F-18]2-fluoro-2-deoxy-D-glucose ([F-18]FDG) and positron emission tomography (PET) were compared with respect to the various kinetic models of the [F-18]FDG method. The kinetic models were conventional homogeneous tissue models of the [F-18]FDG method, with (4K Model) and without (3K Model) a rate constant to account for an apparent loss of [F-18]2-fluoro-2-deoxy-D-glucose-6-phosphate ([F-18]FDG-6-P), and a tissue heterogeneity model (TH Model). When either of the kinetic models designed for homogeneous tissues was applied to heterogeneous tissues, estimates of the rate constant for efflux of [F-18] FDG from the tissue (k2*) and of the rate constant for phosphorylation of [F-18]FDG (k3*) decreased as the duration of the experimental period was increased. When the 4K Model was used, estimates of the rate constant for the apparent dephosphorylation of [F-18]FDG-6-P (k4*) were significantly greater than zero and fell with increasing duration of the experimental period. Although the TH Model included no term to describe an apparent dephosphorylation of [F-18]FDG-6-P, the fit of the TH Model to the time course of total tissue radioactivity was at least as good as and often better than the fit of the 4K Model in the 120-min period following the pulse of [F-18]FDG. Hence, the high estimates of k4* found in PET studies of less-than-or-equal-to 120 min can be explained as the consequence of measuring radioactivity in a heterogeneous tissue and applying a model designed for a homogeneous tissue; there remains no evidence of significant dephosphorylation of [F-18]FDG-6-P in this time period. Furthermore, use of the 4K Model led to an overestimation of rCMR(glc); whole-brain glucose utilization calculated with the 4K Model was >20% higher than values usually obtained in normal humans by the model-independent Kety-Schmidt technique. rCMR(glc) was accurately estimated by the TH Model and, in experimental periods sufficiently long to minimize the effects of tissue heterogeneity, also by the original 3K Model of the deoxyglucose method.
引用
收藏
页码:823 / 834
页数:12
相关论文
共 31 条
[1]   USE OF PET METHODS FOR MEASUREMENT OF CEREBRAL ENERGY-METABOLISM AND HEMODYNAMICS IN CEREBROVASCULAR-DISEASE [J].
BARON, JC ;
FRACKOWIAK, RSJ ;
HERHOLZ, K ;
JONES, T ;
LAMMERTSMA, AA ;
MAZOYER, B ;
WIENHARD, K .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1989, 9 (06) :723-742
[2]  
BIDA GT, 1984, J NUCL MED, V25, P1327
[3]   HUMAN CEREBRAL GLUCOSE-METABOLISM DETERMINED BY POSITRON EMISSION TOMOGRAPHY - A REVISIT [J].
BROOKS, RA ;
HATAZAWA, J ;
DICHIRO, G ;
LARSON, SM ;
FISHBEIN, DS .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1987, 7 (04) :427-432
[4]  
BUDINGER TF, 1978, J NUCL MED, V19, P309
[5]   RELATIONSHIPS BETWEEN EXTRACTION AND METABOLISM OF GLUCOSE, BLOOD-FLOW, AND TISSUE BLOOD-VOLUME IN REGIONS OF RAT-BRAIN [J].
CREMER, JE ;
CUNNINGHAM, VJ ;
SEVILLE, MP .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1983, 3 (03) :291-302
[6]   EFFECT OF VASCULAR ACTIVITY IN THE DETERMINATION OF RATE CONSTANTS FOR THE UPTAKE OF F-18 LABELED 2-FLUORO-2-DEOXY-D-GLUCOSE - ERROR ANALYSIS AND NORMAL VALUES IN OLDER SUBJECTS [J].
EVANS, AC ;
DIKSIC, M ;
YAMAMOTO, YL ;
KATO, A ;
DAGHER, A ;
REDIES, C ;
HAKIM, A .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (06) :724-738
[7]  
HAMACHER K, 1986, J NUCL MED, V27, P235
[8]   CEREBRAL GLUCOSE-METABOLISM AS A FUNCTION OF AGE IN MAN - INFLUENCE OF THE RATE CONSTANTS IN THE FLUORODEOXYGLUCOSE METHOD [J].
HAWKINS, RA ;
MAZZIOTTA, JC ;
PHELPS, ME ;
HUANG, SC ;
KUHL, DE ;
CARSON, RE ;
METTER, EJ ;
RIEGE, WH .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1983, 3 (02) :250-253
[9]   THE INFLUENCE OF TISSUE HETEROGENEITY ON RESULTS OF FITTING NONLINEAR MODEL-EQUATIONS TO REGIONAL TRACER UPTAKE CURVES - WITH AN APPLICATION TO COMPARTMENTAL-MODELS USED IN POSITRON EMISSION TOMOGRAPHY [J].
HERHOLZ, K ;
PATLAK, CS .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1987, 7 (02) :214-229
[10]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .1. EFFECT OF OBJECT SIZE [J].
HOFFMAN, EJ ;
HUANG, SC ;
PHELPS, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (03) :299-308