THE ACCURACY OF AUTOMATED BLOOD-PRESSURE MEASURING DEVICES IN PATIENTS WITH CONTROLLED ATRIAL-FIBRILLATION

被引:2
|
作者
STEWART, MJ [1 ]
GOUGH, K [1 ]
PADFIELD, PL [1 ]
机构
[1] WESTERN GEN HOSP,DEPT MED,EDINBURGH EH4 2XU,MIDLOTHIAN,SCOTLAND
关键词
BLOOD PRESSURE MEASUREMENT; ELECTRONIC SPHYGMOMANOMETER; AMBULATORY BLOOD PRESSURE; ATRIAL FIBRILLATION;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: To determine whether automated blood pressure measuring devices can measure blood pressure accurately in patients with atrial fibrillation. Design: Comparison of the accuracy of two electronic sphygmomanometers [Takeda UA-251 (Takeda) and Copal UA-251 (Copal)] and two ambulatory blood pressure monitors [Accutracker 1 (Accutracker) and SpaceLabs 90207 (SpaceLabs)] with that of a trained observer using a Hawksley random-zero sphygmomanometer (Hawksley), using the sequential same-arm technique. Setting: University teaching hospital: medical wards and outpatient department. Subjects: Twenty-eight patients, mean+/-SD age 72+/-9 years, blood pressure range 90-158/40-96 mmHg, in atrial fibrillation with a controlled ventricular rate. Main outcome measures: The proportion of machine readings >5 mmHg different from the Hawksley reading was compared with that obtained by three sequential Hawksley measurements. The variability of each measuring method was assessed by determining the SDD for the paired readings from each device. Results: Five per cent of Takeda, 5% of Copal, 14% of Accutracker and 21% of SpaceLabs readings could not be obtained. Sequential testing with the Hawksley resulted in an accuracy at the 5-mmHg level of (systolic/diastolic) 79/79%, compared with 64/54% (P<0.05 for diastolic) for the Takeda, 68/75% (NS) for the Copal, 50/36% (P<0.01 for both) for the Accutracker and 50/29% (P<0.01 for systolic, P<0.001 for diastolic) for the SpaceLabs. Intrapatient variability, as assessed by SDD, was 8.3/8.6 mmHg for the Hawksley, similar to that for the Copal (7.7/7.3 mmHg) but higher for the Takeda (11.2/19.7 mmHg), the Accutracker (22.4/26.3 mmHg) and the SpaceLabs (7.5/14.8 mmHg). Conclusions: Accurate measurement of blood pressure with an electronic device is possible in patients who have atrial fibrillation; the Copal UA-251 provides a satisfactory level of accuracy. However, the marked difference between devices and the limited accuracy of the other machines tested here demonstrates the need to ensure that such devices are of proven accuracy in this patient group.
引用
收藏
页码:297 / 300
页数:4
相关论文
共 50 条
  • [1] MEASURING BLOOD-PRESSURE IN THE ELDERLY - DOES ATRIAL-FIBRILLATION INCREASE OBSERVER VARIABILITY
    SYKES, D
    DEWAR, R
    MOHANARUBAN, K
    DONOVAN, K
    NICKLASON, F
    THOMAS, DM
    FISHER, D
    BMJ-BRITISH MEDICAL JOURNAL, 1990, 300 (6718): : 162 - 163
  • [2] OPTIC-NERVE FIBER LOSS IN RELATION TO ATRIAL-FIBRILLATION AND BLOOD-PRESSURE
    PERASALO, R
    RAITTA, C
    PERASALO, J
    INTERNATIONAL OPHTHALMOLOGY, 1992, 16 (4-5) : 259 - 263
  • [3] SPECTRAL-ANALYSIS OF ARTERIAL BLOOD-PRESSURE IN THE RAT DURING ATRIAL-FIBRILLATION
    DANIELS, FH
    LEONARD, EF
    CORTELL, S
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (09) : 566 - 570
  • [4] Automated blood pressure measuring devices: how are they clinically validated for accuracy?
    Jennifer S. Ringrose
    Raj Padwal
    Journal of Human Hypertension, 2023, 37 : 101 - 107
  • [5] Automated blood pressure measuring devices: how are they clinically validated for accuracy?
    Ringrose, Jennifer S.
    Padwal, Raj
    JOURNAL OF HUMAN HYPERTENSION, 2023, 37 (02) : 101 - 107
  • [6] Assessment of blood pressure measurement accuracy by electronic duo control devices at atrial fibrillation patients
    Farsky, S.
    Benova, K.
    Sirotiakova, J.
    Vyskocilova, P.
    Krausova, D.
    EUROPEAN HEART JOURNAL, 2009, 30 : 1034 - 1034
  • [7] ASSESSMENT OF BLOOD PRESSURE MEASUREMENT ACCURACY BY ELECTRONIC DUO CONTROL DEVICES AT ATRIAL FIBRILLATION PATIENTS
    Farsky, S.
    Benova, K.
    Sirotiakova, J.
    Vyskocilova, P.
    Krausova, D.
    JOURNAL OF HYPERTENSION, 2009, 27 : S194 - S194
  • [8] THE ACCURACY OF ELECTRONIC BLOOD-PRESSURE DEVICES
    TERBLANCHE, J
    COMBRINK, LW
    JOURNAL OF DENTAL RESEARCH, 1988, 67 (04) : 781 - 781
  • [9] EVALUATING AUTOMATED BLOOD-PRESSURE DEVICES
    SMALL, CF
    MCEWEN, JA
    COX, NB
    JOHNSON, DL
    LANCET, 1981, 2 (8250): : 805 - 805
  • [10] STANDARDS FOR BLOOD-PRESSURE MEASURING DEVICES
    BEEVERS, DG
    BEEVERS, M
    ZEZULKA, AV
    HORNBY, R
    HEROD, J
    BRITISH MEDICAL JOURNAL, 1987, 294 (6587): : 1614 - 1614