MEASUREMENT OF CONCENTRATION PROFILES INSIDE A NITRITE ION-SELECTIVE ELECTRODE MEMBRANE

被引:68
作者
LI, XZ [1 ]
HARRISON, DJ [1 ]
机构
[1] UNIV ALBERTA,DEPT CHEM,EDMONTON T6G 2G2,ALBERTA,CANADA
关键词
D O I
10.1021/ac00019a018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The behavior of bromo(pyridine)(5,10,15,20-tetraphenyl-porphyrinato)cobaltate (CoTPP(py)Br) as a NO2--selective ion carrier is reported. In dioctyl adipate plasticized poly(vinylchloride) membranes the carrier induces NO2- sensitivity with a slope of -57 mV/decade and selectivity coefficients for Cl-, Br-, H2PO4-, and HPO4(2-) of 5 x 10(-4), 1.6 x 10(-2), 2.1 x 10(-4), and 6.1 x 10(-4), respectively. These membranes respond to pH changes above pH 6 with a slope of -25 to -34 mV/pH unit. A spatial imaging photometer has been developed to image the concentration profile changes inside the membrane in the direction of ion transport with a spatial resolution of less than 5-mu-m. The uptake of H2O is observed by the formation of light scattering centers and exhibits a nonuniform distribution across the membrane. The transport of NO2- is also observed when a CoTPP(py)Br-containing membrane is exposed to NO2- at one membrane/solution interface. The internal concentration profile is described by Fick's laws of diffusion, giving a diffusion coefficient of 5 x 10(-9) cm2/s in the membrane. Evidence for inhomogeneity in the membrane in the direction of charge transport is also obtained.
引用
收藏
页码:2168 / 2174
页数:7
相关论文
共 50 条
[31]   DIRECT MEASUREMENT OF CHLORIDE IN SWEAT WITH AN ION-SELECTIVE ELECTRODE [J].
SZABO, L ;
KENNY, MA ;
LEE, W .
CLINICAL CHEMISTRY, 1973, 19 (07) :727-730
[32]   ONLINE MEASUREMENT OF TRACE CHLORIDE BY ION-SELECTIVE ELECTRODE [J].
WEST, SJ .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1979, 126 (08) :C382-C382
[33]   MEASUREMENT OF CRITICAL MICELLE CONCENTRATION BY ION-SELECTIVE ELECTRODES [J].
NEWBERRY, JE ;
SMITH, V .
COLLOID AND POLYMER SCIENCE, 1978, 256 (05) :494-495
[34]   SELECTIVITY EVALUATION OF AN ION-SELECTIVE ELECTRODE WITH A LIQUID MEMBRANE BY ELECTRODE RESPONSE TO A FOREIGN ION [J].
JYO, A ;
TORIKAI, M ;
ISHIBASH.N .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1974, 47 (11) :2862-2868
[35]   Measurement of the ethanol concentration in a sake using liquid membrane ion-selective electrode containing potassium tetrakis (4-chlorophenyl) [J].
Hattori, T ;
Irikura, H ;
Kato, M .
BUNSEKI KAGAKU, 2001, 50 (10) :679-683
[36]   A hydrogen ion-selective poly(vinyl chloride) membrane electrode based on calix[4]arene as a perchlorate ion-selective electrode [J].
Canel, Esin ;
Erden, Sevcan ;
Ozel, Ayca Demirel ;
Memon, Sahahabuddin ;
Yilmaz, Mustafa ;
Kilic, Esma .
TURKISH JOURNAL OF CHEMISTRY, 2008, 32 (03) :323-332
[37]   The determination of the total concentration of alkyl sulfates by the ion-selective electrode [J].
Kereichuk, AS ;
Pigul, IN ;
Guambe, Z .
RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 1996, 32 (09) :1056-1059
[38]   ION-SELECTIVE MEMBRANE ELECTRODES FOR ORGANIC ANALYZE - LIQUID MEMBRANE - ELECTRODE SELECTIVE TO ACETYLCHOLINE [J].
HOPIRTEAN, E ;
MIKLOS, M .
REVISTA DE CHIMIE, 1978, 29 (12) :1178-1181
[39]   Chemical Modification of Polymer Ion-Selective Membrane Electrode Surfaces [J].
Pawlak, Marcin ;
Bakker, Eric .
ELECTROANALYSIS, 2014, 26 (06) :1121-1131
[40]   CARBONATE ION-SELECTIVE MEMBRANE-ELECTRODE WITH IMPROVED CHARACTERISTICS [J].
SCOTT, W ;
CHAPOTEAU, E ;
JENSEN, M ;
JOHNSON, R ;
RUNCK, A .
CLINICAL CHEMISTRY, 1984, 30 (06) :966-966