Modular titanium alloy neck failure in total hip replacement: analysis of a relapse case

被引:10
|
作者
Ceretti, Marco [1 ]
Falez, Francesco [2 ]
机构
[1] St Filippo & Nicola Hosp, Via Adolfo Omodeo 31 D, I-00179 Rome, Avezzano, Italy
[2] St Spirit Hosp, I-00193 Rome, Italy
来源
SICOT-J | 2016年 / 2卷
关键词
Modular neck; Prosthesis; Fatigue fracture; Total hip arthroplasty;
D O I
10.1051/sicotj/2016009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Modular neck hip prosthesis born in the 1990 with the aim of allowing the surgeon to modify CCD angle, offset and femoral anteversion intra-operatively restoring patient's original biomechanics. In order to achieve the best biomechanics of the reconstructed hip, preoperative planning is essential. In the last few years modularity has been questioned and an argument made for the return to mono block stems due to events of breakage or disconnection of modular components. Fretting or crevice corrosion may lead to failure of such modular device due to the contamination inside the modular coupling or to high loads. We present a case of repetitive modular femoral neck prosthesis fracture.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material
    Grupp, Thomas M.
    Weik, Thomas
    Bloemer, Wilhelm
    Knaebel, Hanns-Peter
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [2] Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material
    Thomas M Grupp
    Thomas Weik
    Wilhelm Bloemer
    Hanns-Peter Knaebel
    BMC Musculoskeletal Disorders, 11
  • [3] Failure analysis of three uncemented titanium-alloy modular total hip stems
    Paliwal, Manish
    Allan, D. Gordon
    Filip, Peter
    ENGINEERING FAILURE ANALYSIS, 2010, 17 (05) : 1230 - 1238
  • [4] Serum Metal Ions with a Titanium Modular Neck Total Hip Replacement System
    Gofton, Wade
    Beaule, Paul E.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (10): : 1781 - 1786
  • [5] Analysis of the stem-sleeve interface in a modular titanium alloy femoral component for total hip replacement
    Kurtz, SM
    Srivastav, S
    Dwyer, K
    Ochoa, J
    Brown, SB
    FUNCTIONAL BIOMATERIALS, 2001, 198-1 : 41 - 68
  • [6] Modular Neck in Primary Total Hip Replacement - A Justifiable Risk?
    Kretzer, J. P.
    Ewerbeck, V.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2015, 153 (03): : 312 - 316
  • [7] Corrosion of modular titanium alloy stems in cementless hip replacement
    Urban, Robert M.
    Gilbert, Jeremy L.
    Jacobs, Joshua J.
    TITANIUM, NIOBIUM, ZIRCONIUM, AND TANTALUM FOR MEDICAL AND SURGICAL APPLICATIONS, 2006, 1471 : 215 - +
  • [8] Early Failure of a Modular Femoral Neck Total Hip Arthroplasty Component A Case Report
    Wilson, David A. J.
    Dunbar, Michael J.
    Amirault, John D.
    Farhat, Zoheir
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (06): : 1514 - 1517
  • [9] A Single-Center Experience With a Titanium Modular Neck Total Hip Arthroplasty
    Gofton, Wade T.
    Illical, Emmanuel M.
    Feibel, Robert J.
    Kim, Paul R.
    Beaule, Paul E.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (08): : 2450 - 2456
  • [10] Modular femoral neck failure after revision of a total hip arthroplasty: a finite element analysis
    Jan Zajc
    Jožef Predan
    Nenad Gubeljak
    Andrej Moličnik
    Samo K. Fokter
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 717 - 723