Verification of CyberKnife Dose Distributions with Gafchromic EBT2 Film

被引:0
作者
Koksal, Canan [1 ]
Akbas, Ugur [1 ]
Kesen, Nazmiye Donmez [1 ]
Bilge, Hatice [1 ]
Kemikler, Gonul [1 ]
机构
[1] Istanbul Univ, Dept Med Phys, Inst Oncol, Istanbul, Turkey
来源
TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY | 2018年 / 33卷 / 04期
关键词
CyberKnife; film dosimetry; gamma evaluation; quality assurance;
D O I
10.5505/tjo.2018.1765
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
OBJECTIVE CyberKnife (CK) system is more sophisticated than the conventional methods; therefore, strict quality assurance tests are required. To ensure that the treatment is delivered as planned, the verification of the treatment plan should be performed with specific dosimetry tools. This study aims to verify the CK treatment plans generated for patients with intracranial tumors using Gafchromic EBT2 film. METHODS The CK plans of ten patients with intracranial tumors were selected for this study. The plans were transferred to computed tomography images of the anthropomorphic head phantom. The phantom containing the film was irradiated using 6D skull tracking method. The dose distributions calculated by TPS were compared with those measured by film using gamma analysis method. RESULTS In the gamma-index method, the average passing rate for the 3%/3 mm criterion was found to be 93.9 +/- 4.8%. The gamma passing rate for Iris-collimator-based plans yielded slightly lower than that for fixed-collimator-based plans. CONCLUSION In conclusion, this study indicates that Gafchromic EBT2 film is a utilizable dosimeter for quality assurance of the CK treatment plans. It is recommended to use the EBT2 film for verification of the CK treatment plans before delivery to the patient.
引用
收藏
页码:147 / 153
页数:7
相关论文
共 14 条
[1]  
Agazaryan Nzhde, 2003, J Appl Clin Med Phys, V4, P40, DOI 10.1120/1.1525243
[2]   A comprehensive study of the Gafchromic EBT2 radiochromic film. A comparison with EBT [J].
Andres, C. ;
del Castillo, A. ;
Tortosa, R. ;
Alonso, D. ;
Barquero, R. .
MEDICAL PHYSICS, 2010, 37 (12) :6271-6278
[3]   Plan delivery quality assurance for CyberKnife: Statistical process control analysis of 350 film-based patient-specific QAs [J].
Bellec, J. ;
Delaby, N. ;
Jouyaux, F. ;
Perdrieux, M. ;
Bouvier, J. ;
Sorel, S. ;
Henry, O. ;
Lafond, C. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 39 :50-58
[4]   Quantitative analysis of patient-specific dosimetric IMRT verification [J].
Budgell, GJ ;
Perrin, BA ;
Mott, JHL ;
Fairfoul, J ;
Mackay, RI .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (01) :103-119
[5]   Factors Affecting the Choice of Market Entry Modes in the African Telephony Industry [J].
Chanakira, Maxwell .
INTERNATIONAL JOURNAL OF APPLIED BEHAVIORAL ECONOMICS, 2012, 1 (02) :1-15
[6]   Post-irradiation colouration of Gafchromic EBT radiochromic film [J].
Cheung, T ;
Butson, MJ ;
Yu, PKN .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20) :N281-N285
[7]   Report of AAPM TG 135: Quality assurance for robotic radiosurgery [J].
Dieterich, Sonja ;
Cavedon, Carlo ;
Chuang, Cynthia F. ;
Cohen, Alan B. ;
Garrett, Jeffrey A. ;
Lee, Charles L. ;
Lowenstein, Jessica R. ;
d'Souza, Maximian F. ;
Taylor, David D., Jr. ;
Wu, Xiaodong ;
Yu, Cheng .
MEDICAL PHYSICS, 2011, 38 (06) :2914-2936
[8]   EBT2 radiochromic film for quality assurance of complex IMRT treatments of the prostate: micro-collimated IMRT, RapidArc, and TomoTherapy [J].
Kairn, T. ;
Hardcastle, N. ;
Kenny, J. ;
Meldrum, R. ;
Tome, W. A. ;
Aland, T. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (03) :333-343
[9]   The CyberKnife® Robotic Radiosurgery System in 2010 [J].
Kilby, W. ;
Dooley, J. R. ;
Kuduvalli, G. ;
Sayeh, S. ;
Maurer, C. R., Jr. .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (05) :433-452
[10]   Evaluation of the gamma dose distribution comparison method [J].
Low, DA ;
Dempsey, JF .
MEDICAL PHYSICS, 2003, 30 (09) :2455-2464