DIFFERENCES IN THE PSEUDOELASTICITY BEHAVIOR OF NICKEL-TITANIUM ORTHODONTIC WIRES

被引:15
作者
GIL, FJ [1 ]
PLANELL, JA [1 ]
LIBENSON, C [1 ]
机构
[1] UNIV BARCELONA,FAC ODONTOL,DEPT CIENCIAS MORFOL & ODONTOESTOMATOL,BARCELONA 7,SPAIN
关键词
D O I
10.1007/BF00122281
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The variations in superelasticity behaviour have been studied for three orthodontics wires. Chemical compositions, microstructures, transformation temperatures and induced martensitic transformation stresses have been determined in each alloy. Tension tests were carried out at room temperature (20-degrees-C) and body temperature with physiological environment at 37-degrees-C in order to determine the small force which the orthodontist can apply for bone remodelling processes.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 50 条
[31]   Force level of small diameter nickel-titanium orthodontic wires ligated with different methods [J].
Rodrigo Hitoshi Higa ;
José Fernando Castanha Henriques ;
Guilherme Janson ;
Murilo Matias ;
Karina Maria Salvatore de Freitas ;
Fernanda Pinelli Henriques ;
Manoela Fávaro Francisconi .
Progress in Orthodontics, 18
[32]   The effect of temperature on the mechanical behavior of nickel-titanium orthodontic initial archwires [J].
Lombardo, Luca ;
Toni, Giorgia ;
Stefanoni, Filippo ;
Mollica, Francesco ;
Guarneri, Maria Paola ;
Siciliani, Giuseppe .
ANGLE ORTHODONTIST, 2013, 83 (02) :298-305
[33]   The effects of temperature changes on the phase transformation and mechanical properties in nickel-titanium orthodontic wires. [J].
Lee, Y. -H. ;
Lim, B. -S. ;
Lee, Y. -K. ;
Kim, C. -W. .
JOURNAL OF DENTAL RESEARCH, 2003, 82 :B342-B342
[34]   Fatigue of orthodontic nickel-titanium (NiTi) wires in different fluids under constant mechanical stress [J].
Prymak, O ;
Klocke, A ;
Kahl-Nieke, B ;
Epple, M .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2004, 378 (1-2) :110-114
[35]   A COMPARISON OF NICKEL-TITANIUM WIRES BY TENSILE TEST [J].
STANTON, G ;
MORI, T ;
SIMS, M .
JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) :756-756
[36]   A Comparative Evaluation of Surface Hardness and Nanomechanical Properties of Nickel-Titanium Orthodontic Wires: An In Vitro Study [J].
Santhakumari, Prasanth Prathapan ;
Raja, Vighnesh Varma ;
Kalarickal, Biju ;
Parambil, Mohamed Haris Thavalam ;
Sebastian, Joseph ;
Cheeramelil, Jacob .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
[37]   NICKEL-TITANIUM - NITINOL WIRES AS CLASPS FOR DENTURES [J].
LING, BC ;
KALSOM, I .
JOURNAL OF DENTAL RESEARCH, 1989, 68 (04) :740-740
[38]   Loss of pseudoelasticity in nickel-titanium sub-micron compression pillars [J].
Frick, C. P. ;
Orso, S. ;
Arzt, E. .
ACTA MATERIALIA, 2007, 55 (11) :3845-3855
[39]   Nickel concentration in the saliva of patients with nickel-titanium orthodontic appliances [J].
Petoumenou, Evangelia ;
Arndt, Martin ;
Keilig, Ludger ;
Reimann, Susanne ;
Hoederath, Hildegard ;
Eliades, Theodore ;
Jaeger, Andreas ;
Bourauel, Christoph .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (01) :59-65
[40]   Corrosion Behavior of Coated and Uncoated Nickel-Titanium Orthodontic Wires in Artificial Saliva with Short-term Prophylactic Fluoride Treatment [J].
Katic, Visnja ;
Buljan, Zorana Ivankovic ;
Spalj, Stjepan ;
Curkovic, Helena Otmacic .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (05) :4160-4170