CYCLONE PRESSURE-DROP AND EFFICIENCY WITH AND WITHOUT AN INLET VANE

被引:20
作者
COMAS, M [1 ]
COMAS, J [1 ]
CHETRIT, C [1 ]
CASAL, J [1 ]
机构
[1] UNIV POLITECN CATALUNYA,ESCOLA TECH SUPER ENGN IND BARCELONA,DEPT CHEM ENGN,E-08028 BARCELONA,SPAIN
关键词
D O I
10.1016/0032-5910(91)80095-Z
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Cyclone pressure drop decreases when dust concentration in the gas increases, and when an inlet vane is installed. In this work, experimental data have been obtained for two different configurations (with and without inlet vane) in order to study these effects; these data have been compared with results published by other authors. Empirical correlations have been obtained to predict pressure drop as a function of dust load for these operating conditions. Finally, the influence of an inlet vane on cyclone collection efficiency has been studied; for large particles, the efficiency is not affected, but with smaller particle diameters, the inlet vane causes a slight reduction in collection efficiency.
引用
收藏
页码:143 / 148
页数:6
相关论文
共 15 条
[1]  
Barth W., 1956, BRENNSTOFF WA RME KR, V8, P1, DOI DOI 10.1016/J.CEJ.2008.10.022
[2]  
BASKAKOV AP, 1988, CIRCULATING FLUIDIZE, P233
[3]   THE EFFECT OF PARTICULATE SOLIDS ON PRESSURE-DROP ACROSS A CYCLONE [J].
BEECKMANS, JM ;
MORIN, B .
POWDER TECHNOLOGY, 1987, 52 (03) :227-232
[4]  
BOHNET M, 1983, GER CHEM ENG, V4, P211
[5]  
BRIGGS LW, 1946, T AM INST CHEM ENG, V42, P511
[6]   PRESSURE-DROP REDUCTION IN CYCLONES [J].
BROWNE, JM ;
STRAUSS, W .
ATMOSPHERIC ENVIRONMENT, 1978, 12 (05) :1213-1221
[7]  
CAPLAN KJ, 1977, AIR POLLUTION, P97
[8]  
CASAL J, 1988, 5 ACT JORN FLUID OV, V1, P62
[9]  
KIEGEL E, 1968, AUFBEREITUNGS TECHNI, V9, P1
[10]  
Mothes H., 1985, GER CHEM ENG, V8, P223