HIGH-ACCURACY MOLECULAR-WEIGHT DETERMINATION AND VARIATION CHARACTERIZATION OF PROTEINS UP TO 80-KU BY IONSPRAY MASS-SPECTROMETRY

被引:105
作者
FENG, R
KONISHI, Y
BELL, AW
机构
[1] Bioteclmology Research Institute, National Research Council of Canada, Montreal, H4P 2R2, Quebec
关键词
D O I
10.1016/1044-0305(91)85005-Q
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A quadrupole mass spectrometer with an ionspray interface was used to measure the molecular weight (MW) of proteins up to 80,000 u. With the improvements in instrument calibration by a statistical averaging method and in data analysis by a gaussian curve-fitting method, precision of MW determination as high as 12 ppm was achieved with equine myoglobin (MW 16,950.4 +/- 0.2 u). Exact MW determination of three components in cerato-ulmin revealed that the two minor ones had lost amino acid residues Ser and Ser-Asp, respectively, from the major component (MW 7618.4 +/- 0.2 u). MW classification of eight components in the Fab fragment of a monoclonal antibody revealed that one set of four had MW approximately 47,540 u and the other approximately 47,640 u. The MW difference of 100.2 +/- 0.6 u between fragment 1 and 2, attributed to inhomogeneous cleavage at the Fab C-terminus, was probably due to one additional Thr in 1. The MW of bovine serum albumin (BSA) was found to be 66,431.5 +/- 1.3 u, approximately 164 u higher than the calculated sequence MW, most probably because of the incorrectness in the previously reported BSA amino acid sequence. The MW of human serum transferrin (79,556.8 +/- 1.7 u) was shown to be 4414 u higher than the sequence MW, pointing to a glycosylation of 22.7 sugar units in this protein. The greater complexity in bovine serum transferrin (MW 78,030.5 +/- 1.8 and 78,326 +/- 3.3 u for the two major components) was correlated with the heterogeneity in the glycosylation.
引用
收藏
页码:387 / 401
页数:15
相关论文
共 46 条
[1]   IRON TRANSPORT AND STORAGE PROTEINS [J].
AISEN, P ;
LISTOWSKY, I .
ANNUAL REVIEW OF BIOCHEMISTRY, 1980, 49 :357-393
[2]   HIGH-ACCURACY MOLECULAR MASS DETERMINATION OF PROTEINS USING MATRIX-ASSISTED LASER DESORPTION MASS-SPECTROMETRY [J].
BEAVIS, RC ;
CHAIT, BT .
ANALYTICAL CHEMISTRY, 1990, 62 (17) :1836-1840
[3]  
BERKEL GJV, 1990, 38TH P ASMS C MASS S, P12
[4]  
BERKEL GJV, 1990, ANAL CHEM, V62, P1284
[5]   PEPTIDE SEQUENCING USING THE COMBINATION OF EDMAN DEGRADATION, CARBOXYPEPTIDASE DIGESTION AND FAST ATOM BOMBARDMENT MASS-SPECTROMETRY [J].
BRADLEY, CV ;
WILLIAMS, DH .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1982, 104 (04) :1223-1230
[6]  
BROCK JH, 1985, METALLOPROTEINS 2, P183
[7]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[8]   ORIGIN AND REMOVAL OF ADDUCTS (MOLECULAR MASS = 98-U) ATTACHED TO PEPTIDE AND PROTEIN IONS IN ELECTROSPRAY IONIZATION MASS-SPECTRA [J].
CHOWDHURY, SK ;
KATTA, V ;
BEAVIS, RC ;
CHAIT, BT .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1990, 1 (05) :382-388
[9]   AN ELECTROSPRAY-IONIZATION MASS-SPECTROMETER WITH NEW FEATURES [J].
CHOWDHURY, SK ;
KATTA, V ;
CHAIT, BT .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (03) :81-87
[10]   PROBING CONFORMATIONAL-CHANGES IN PROTEINS BY MASS-SPECTROMETRY [J].
CHOWDHURY, SK ;
KATTA, V ;
CHAIT, BT .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (24) :9012-9013