Decoupled control of active and reactive power of a wind turbine based on DFIG and matrix converter

被引:12
作者
Ghoudelbourk, S. [1 ]
Dib, D. [2 ]
Omeiri, A. [1 ]
机构
[1] Univ Badji Mokhtar Annaba, Dept Elect Engn, Annaba, Algeria
[2] Univ Larbi Tebessi, Dept Elect Engn, Tebessa 12002, Algeria
来源
ENERGY SYSTEMS-OPTIMIZATION MODELING SIMULATION AND ECONOMIC ASPECTS | 2016年 / 7卷 / 03期
关键词
Control; Matrix converter; DFIG; Fuzzy logic; PI regulator;
D O I
10.1007/s12667-015-0177-1
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Wind turbines chains are increasingly used in the world and provide power, become important with technological developments. Through this present paper, we present work to improve the performance of wind turbines by the integration of a combined control mode with three different techniques: a classic PI controller, a Fuzzy logic controller and a matrix inverter. The results were much better compared to a combination without the matrix converter where the control decoupling between the active and reactive power is obtained successfully in more than a reduction of the harmonic distortion THD is very acceptable, which promotes improving the power quality produced by this type of wind chain.
引用
收藏
页码:483 / 497
页数:15
相关论文
共 11 条
[1]   An empirical model of power curve of a wind turbine [J].
Das A.K. .
Energy Systems, 2014, 5 (03) :507-518
[2]   Optimal power flow: A bibliographic survey I Formulations and deterministic methods [J].
Frank S. ;
Steponavice I. ;
Rebennack S. .
Energy Systems, 2012, 3 (03) :221-258
[3]  
Ganesh R., 2014, INT J INNOV RES SCI, V3
[4]  
Garg A., 2015, EVOLVING FUNCTIONAL, P1
[5]  
Hosseini SH, 2003, CCA 2003: PROCEEDINGS OF 2003 IEEE CONFERENCE ON CONTROL APPLICATIONS, VOLS 1 AND 2, P1088
[6]   Direct Active and Reactive Power Regulation of DFIG Using Sliding-Mode Control Approach [J].
Hu, Jiabing ;
Nian, Heng ;
Hu, Bin ;
He, Yikang ;
Zhu, Z. Q. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (04) :1028-1039
[7]   An Improved Low-Voltage Ride-Through Control Strategy of Doubly Fed Induction Generator During Grid Faults [J].
Hu, Sheng ;
Lin, Xinchun ;
Kang, Yong ;
Zou, Xudong .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (12) :3653-3665
[8]   Modeling and control design of a stand alone wind energy conversion system based on functional model predictive control [J].
Kassem, Ahmed M. .
Energy Systems, 2012, 3 (03) :303-323
[9]  
Poitiers F., 2009, ELSEVIER ELECT POWER, V79
[10]  
Rezaoui M.M., 2010, STUDY OUTPUT VOLTAGE