FLOW-CYTOMETRY ANALYSIS OF THE EXPRESSION OF NEUTROPHIL FMLP RECEPTORS

被引:27
|
作者
ALLEN, CA [1 ]
BROOM, MF [1 ]
CHADWICK, VS [1 ]
机构
[1] UNIV OTAGO,SCH MED,DEPT EXPTL MED,POB 913,DUNEDIN,NEW ZEALAND
关键词
FLOW CYTOMETRY; NEUTROPHIL; FORMYL-METHIONINE-LEUCINE-PHENYLALANINE RECEPTOR;
D O I
10.1016/0022-1759(92)90246-P
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The number of cell surface FMLP receptors expressed by peripheral blood neutrophils taken from healthy individuals was quantitated using a direct fluorescence label analysed on the FACScan. Receptor numbers, assayed on cells from heparinised blood prepared at 4-degrees-C or 37-degrees-C or in the presence of LPS (30 ng/ml) were 12,540 +/- SD 2413, 18,588 +/- 4938 and 45,041 +/- 10,744 respectively. Anticoagulation with EGTA resulted in 25-30% greater basal receptor numbers but had no effect on receptor level after maximal stimulation with LPS. Double labelling with a neutrophil-specific mAb showed that the entire neutrophil population expressed FMLP receptors.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 50 条
  • [1] FURTHER CHARACTERIZATION OF THE NEUTROPHIL OXIDATIVE BURST BY FLOW-CYTOMETRY
    SMITH, JA
    WEIDEMANN, MJ
    JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 162 (02) : 261 - 268
  • [2] ANALYSIS OF PLOIDY IN A PLANARIAN BY FLOW-CYTOMETRY
    HOSHINO, K
    OHNISHI, K
    YOSHIDA, W
    SHINOZAWA, T
    HYDROBIOLOGIA, 1991, 227 : 175 - 178
  • [3] DNA ANALYSIS WITH FLOW-CYTOMETRY AND IMAGE CYTOMETRY IN COLORECTAL POLYPS
    TORRESAN, F
    ZANELLA, L
    MATTAROZZI, A
    QUIROGA, A
    BACCHINI, P
    BERTONI, F
    GANDOLFI, L
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1994, 8 (12): : 1412 - 1416
  • [4] DNA ANALYSIS OF ORAL LEUKOPLAKIA BY FLOW-CYTOMETRY
    SAITO, T
    NOTANI, K
    MIURA, H
    FUKUDA, H
    MIZUNO, S
    SHINDOH, M
    AMEMIYA, A
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1991, 20 (05) : 259 - 263
  • [5] Use of standard for quantitation of neutrophil adherence receptors by flow cytometry
    Latger-Cannard, V
    Regnault, V
    Dumas, D
    Virion, JM
    Schooneman, JF
    Stoltz, JF
    Lecompte, T
    ANNALES DE BIOLOGIE CLINIQUE, 2000, 58 (03) : 337 - 343
  • [6] Limits of flow-cytometry histogram analysis methods to assess bladder tumour antigen expression
    Chabanas, A
    Rambeaud, JJ
    Huo, HH
    Seigneurin, D
    Lawrence, JJ
    ANALYTICAL CELLULAR PATHOLOGY, 1997, 13 (01): : 39 - 47
  • [7] FLOW-CYTOMETRY IN THE DIAGNOSIS OF CANCER
    ORFAO, A
    CIUDAD, J
    GONZALEZ, M
    LOPEZ, A
    ABAD, MDM
    BOUZA, JIP
    CRUZ, JJ
    ALONSO, AG
    MIGUEL, JFS
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1995, 55 : 145 - 152
  • [8] Flow-cytometry analysis reveals persister resuscitation characteristics
    Mohiuddin, Sayed Golam
    Kavousi, Pouria
    Orman, Mehmet A.
    BMC MICROBIOLOGY, 2020, 20 (01)
  • [9] Flow-cytometry analysis reveals persister resuscitation characteristics
    Sayed Golam Mohiuddin
    Pouria Kavousi
    Mehmet A. Orman
    BMC Microbiology, 20
  • [10] MEASUREMENT OF ALLOANTIBODY BY FLOW-CYTOMETRY
    LEENAERTS, PL
    DERUYSSCHER, D
    VANDEPUTTE, M
    WAER, M
    JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 130 (01) : 73 - 79