QUASI-OPTICAL MEASUREMENT OF CARCINOTRON PHASE NOISE AT 350 GHZ

被引:2
|
作者
VANARDENNE, A [1 ]
MELIS, W [1 ]
机构
[1] UNIV GRONINGEN,DEPT APPL PHYS,9700 AB GRONINGEN,NETHERLANDS
关键词
Electric Measurements - Electron Tubes; Backward Wave--Millimeter Waves - Optical Variables Measurement - Phase Locked Loops;
D O I
10.1049/el:19880964
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Phase noise of a single carcinotron operating at 350 GHz, at offset frequencies in the range 105-107 Hz, from the carrier has been measured. A quasi-optical analogue of the delay line frequency discriminator method was used, demonstrating a simple method capable of measuring phase noise in the (sub)mm region. The results obtained are of practical use in the design of phase locked systems, in the wavelength region used.
引用
收藏
页码:1411 / 1413
页数:3
相关论文
共 50 条
  • [11] FDTD simulation and measurement of a 90GHz quasi-optical annular slot receiver
    Yeap, SB
    Parini, CG
    Dupuy, JA
    Rayner, MR
    IEE PROCEEDINGS-MICROWAVES ANTENNAS AND PROPAGATION, 2005, 152 (02) : 117 - 123
  • [12] ACTIVE AND PASSIVE TERAHERTZ MEASUREMENT-TECHNOLOGY WITH A FLEXIBLE QUASI-OPTICAL MEASUREMENT SYSTEM AT 600 GHZ
    BRUNE, J
    ARCHIV FUR ELEKTROTECHNIK, 1993, 77 (01): : 71 - 75
  • [13] 28 GHZ OMNIDIRECTIONAL QUASI-OPTICAL TRANSMITTER ARRAY
    VAUGHAN, MJ
    COMPTON, RC
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1995, 43 (10) : 2507 - 2509
  • [14] Quasi-optical microwave pulse compressor at 34 GHz
    Vikharev, AL
    Danilov, YY
    Gorbachev, AM
    Kuzikov, SV
    Koshurinov, YI
    Paveliev, VG
    Petelin, MI
    Hirshfield, JL
    ADVANCED ACCELERATOR CONCEPTS, 2002, 647 : 448 - 458
  • [15] Quasi-optical mode converter for 95 GHz gyrotron
    Laboratory of High Power Microwave Technology, Institute of Applied Electronics, CAEP, P. O. Box 919-1016, Mianyang 621900, China
    Qu, J. (acemichel@163.com), 1600, Editorial Office of High Power Laser and Particle Beams, P.O. Box 919-805, Mianyang, 621900, China (24):
  • [16] Design of a 17.14 GHz quasi-optical pulse compressor
    Petelin, MI
    Kuzikov, SV
    Danilov, YY
    Granatstein, VL
    Nusinovich, GS
    ADVANCED ACCELERATOR CONCEPTS, EIGHTH WORKSHOP, 1999, 472 : 1014 - 1019
  • [17] Design of Quasi-Optical 500GHz Duplexer
    Deng, Jun
    Wang, Xue-tian
    Liu, Chi
    Wang, Wei
    PROCEEDINGS OF 2014 3RD ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION (APCAP 2014), 2014, : 1267 - 1270
  • [18] Broadband oscillator measurement setup in flexible quasi-optical technique for the frequency range 170 GHz to 260 GHz
    Brune, Jochen
    Steup, Dominik
    Stoeckel, Bernd
    1600, Fachverlag Schiele & Schoen GmbH, Berlin, Germany (49): : 5 - 6
  • [19] Quasi-optical analysis of binary optical components at 100GHz
    Lanigan, W
    Mahon, R
    Murphy, JA
    Trappe, N
    CONFERENCE DIGEST OF THE 2004 JOINT 29TH INTERNATIONAL CONFERENCE ON INFRARED AND MILLIMETER WAVES AND 12TH INTERNATIONAL CONFERENCE ON TERAHERTZ ELECTRONICS, 2004, : 589 - 590
  • [20] A HIGHLY SENSITIVE MILLIMETER-WAVE QUASI-OPTICAL FM NOISE MEASUREMENT SYSTEM
    SMITH, GM
    LESURF, JCG
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1991, 39 (12) : 2229 - 2236