KERATOPROSTHESIS WITH BIOCOLONIZABLE MICROPOROUS FLUOROCARBON HAPTIC - PRELIMINARY-RESULTS IN A 24-PATIENT STUDY

被引:45
作者
LEGEAIS, JM
RENARD, G
PAREL, JM
SAVOLDELLI, M
POULIQUEN, Y
机构
[1] HOP HOTEL DIEU, DEPT OPHTHALMOL, PARIS, FRANCE
[2] UNIV MIAMI, SCH MED, BASCOM PALMER EYE INST, CTR OPHTHALM BIOPHYS, CORAL GABLES, FL 33124 USA
关键词
D O I
10.1001/archopht.1995.01100060083038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Most complications of a keratoprosthesis occur at the tissue-to-implant interface. The ideal prosthesis would eliminate this interface by having the tissue actually grow into the supporting material. We present a prospective clinical human study of a novel biocolonizable keratoprosthesis in 24 eyes of 24 patients. Design: To promote implant stability, the 9-mm-diameter haptic was fashioned using a custom-made microporous fluorocarbon with a 4-mm-diameter, 2.67-mm-long, central optic made of medical grade polymethylmethacrylate, giving a global visual field of 110 degrees to 130 degrees. Only bilaterally blind patients with untreatable corneal diseases were included in the study. The haptic was inserted into a lamellar pocket delaminated in the stroma, and the optic was positioned through a hole trephined in the central cornea. Results: The average follow-up was 15.7 months (range, 4 to 28 months). The host corneal fibroblasts penetrated and proliferated into the peripheral microporous fluorocarbon and provided anchorage between the cornea and prosthesis. Seventeen patients (70.8%) had visual acuity improvements. Mean corrected final visual acuity was 20/100 (range, zone to 20/400). Five anatomic failures occurred in the first 6 months (three extrusions, one dislocation of the optic, and one endophthalmitis). We had one case (4.1%) of treatable glaucoma. We successfully removed four of five retroprosthetic membranes that had occurred. No retinal detachment occurred. Conclusion: The biocompatible inert microporous polymer did not eliminate all mechanical complications associated with a keratoprosthesis.
引用
收藏
页码:757 / 763
页数:7
相关论文
共 29 条
  • [1] BARBER JC, 1980, INVEST OPHTH VIS SCI, V19, P182
  • [3] INTERPENETRATING POLYMER NETWORK (IPN) AS A PERMANENT JOINT BETWEEN THE ELEMENTS OF A NEW-TYPE OF ARTIFICIAL CORNEA
    CHIRILA, TV
    VIJAYASEKARAN, S
    HORNE, R
    CHEN, YC
    DALTON, PD
    CONSTABLE, IJ
    CRAWFORD, GJ
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (06): : 745 - 753
  • [4] CHOYCE DP, 1973, OPHTHALMIC SURG LAS, V4, P23
  • [5] TISSUE INTERACTION WITH HYDROGEL SPONGES IMPLANTED IN THE RABBIT CORNEA
    CRAWFORD, GJ
    CONSTABLE, IJ
    CHIRILA, TV
    VIJAYASEKARAN, S
    THOMPSON, DE
    [J]. CORNEA, 1993, 12 (04) : 348 - 357
  • [6] SOME FACTORS INFLUENCING OUTCOME AFTER KERATOPROSTHESIS SURGERY
    DOHLMAN, CH
    DOANE, MG
    [J]. CORNEA, 1994, 13 (03) : 214 - 218
  • [7] DOHLMAN CH, 1987, AM J OPHTHALMOL, V103, P331
  • [8] Girard L J, 1977, Trans Sect Ophthalmol Am Acad Ophthalmol Otolaryngol, V83, P252
  • [9] FIBRONECTIN ADSORPTION ON MATERIAL-SURFACES
    GRINNELL, F
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 516 : 280 - 290
  • [10] GUIDOIN R, 1992, BIOMATERIALS, V13, P281, DOI 10.1016/0142-9612(92)90051-O