EFFECTS OF UPSTREAM WALL HEATING ON MIXED CONVECTION IN SEPARATED FLOWS

被引:11
作者
ABUMULAWEH, HI
ARMALY, BF
CHEN, TS
机构
[1] Department of Mechanical and Aerospace Engineering and Engineering Mechanics, University of Missouri-Rolla, Rolla, 65401, MO
基金
美国国家科学基金会;
关键词
Anemometers - Boundary layer flow - Flow visualization - Geometry - Heat transfer - Laminar flow - Laser Doppler velocimeters - Nusselt number - Reynolds number - Temperature distribution - Thermal conductivity - Thermal expansion;
D O I
10.2514/3.729
中图分类号
O414.1 [热力学];
学科分类号
摘要
Measurements and predictions are reported for buoyancy-assisting, Laminar mixed convection boundary-layer flow of air along a two-dimensional, vertical backward-facing step, in which the upstream wall and the step are heated to a uniform temperature while the downstream wall is heated to the same or different uniform temperature. The experiments were performed on a backward-facing step geometry, with a step height of 0.8 cm, over a range of freestream velocities 0.26 less than or equal to u(infinity) less than or equal to 0.41 mis and a range of temperature differences 0 less than or equal to Delta T less than or equal to 34 degrees C between the heated walls and the freestream. Laser Doppler velocimeter and cold-wire anemometer were utilized to measure, respectively, the air velocity and the temperature simultaneously. Flow visualizations were also performed to determine the flow reattachment length behind the backward-facing step. Reported measurements are Limited to the case where the upstream wall and the step are heated to the same uniform temperature as the downstream wall, but numerical results are presented for the cases where these two temperatures are different and also for the situation when the upstream wall and the step are maintained as adiabatic surfaces. These results reveal that heating of the upstream wall and the step significantly affects the reattachment length, the velocity and temperature distributions, and the rate of heat transfer downstream of the backward-facing step.
引用
收藏
页码:715 / 721
页数:7
相关论文
共 5 条
[1]   MEASUREMENTS OF LAMINAR MIXED CONVECTION IN BOUNDARY-LAYER FLOW OVER HORIZONTAL AND INCLINED BACKWARD-FACING STEPS [J].
ABUMULAWEH, HI ;
ARMALY, BF ;
CHEN, TS .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1993, 36 (07) :1883-1895
[2]   MEASUREMENTS IN BUOYANCY-ASSISTING SEPARATED FLOW BEHIND A VERTICAL BACKWARD-FACING STEP [J].
BAEK, BJ ;
ARMALY, BF ;
CHEN, TS .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1993, 115 (02) :403-408
[3]  
HONG B, 1992, 1992 ASME WINT ANN M, V213, P73
[4]   MEASUREMENTS AND PREDICTIONS OF LAMINAR MIXED CONVECTION FLOW ADJACENT TO A VERTICAL SURFACE [J].
RAMACHANDRAN, N ;
ARMALY, BF ;
CHEN, TS .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1985, 107 (03) :636-641
[5]   PC SOLUTIONS FOR HEAT-TRANSFER AND FLUID-FLOW DOWNSTREAM OF AN ABRUPT, ASYMMETRIC ENLARGEMENT IN A CHANNEL [J].
SPARROW, EM ;
CHUCK, W .
NUMERICAL HEAT TRANSFER, 1987, 12 (01) :19-40