LONG-TERM REPRODUCIBILITY, OF AMBULATORY BLOOD-PRESSURE

被引:0
作者
MANSOOR, GA [1 ]
MCCABE, EJ [1 ]
WHITE, WB [1 ]
机构
[1] UNIV CONNECTICUT,SCH MED,DEPT MED,HYPERTENS & VASC DIS SECT,FARMINGTON,CT 06032
关键词
AMBULATORY BLOOD PRESSURE; REPRODUCIBILITY;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: To compare the reproducibility of ambulatory and office blood pressure readings in established hypertensive subjects when studies are repeated at extended time intervals. Subjects: Twenty-five hypertensive patients (office diastolic blood pressure greater than or equal to 90 mmHg) who were off antihypertensive therapy for at least 4 weeks and had repeat office and ambulatory blood pressures at least 3 months apart under similar study conditions. Methods: On the same day, patients underwent office blood pressure readings measured by mercury column sphygmomanometry and then by ambulatory blood pressure monitoring. Ambulatory blood pressure monitoring was done for 24 h, and awake and sleep periods were divided according to a diary kept by each patient. A second study was performed in an identical manner at a mean +/- SD interval of 23 +/- 24 months (range 3-80, median 15). The agreement between studies was assessed by correlation coefficients, coefficients of variation and standard deviation of the differences (SDD). Results: There were no significant differences in office, 24-h, awake and sleep mean blood pressures between the two studies. Mean 24-h systolic and diastolic blood pressures were 16 and 14 mmHg lower, respectively, than office blood pressure values. Correlation coefficients were significantly higher for 24-h ambulatory blood pressure than office blood pressure, whereas the SDD between visits was significantly lower for 24-h ambulatory blood pressure than office blood pressure. Conclusions: These data demonstrate that long-term reproducibility of ambulatory blood pressure is superior to that for office measurement. One implication of this finding is that, in long-term clinical pharmacology trials utilizing ambulatory blood pressure, fewer subjects would be required than for studies that used office blood pressure end-points.
引用
收藏
页码:703 / 708
页数:6
相关论文
共 50 条
  • [31] PROGNOSTIC VALUE OF AMBULATORY BLOOD-PRESSURE MONITORING
    OMBONI, S
    RAVOGLI, A
    PARATI, G
    ZANCHETTI, A
    MANCIA, G
    JOURNAL OF HYPERTENSION, 1991, 9 : S25 - S28
  • [32] AMBULATORY BLOOD-PRESSURE RECORDINGS IN CHILDREN AND ADOLESCENTS
    HARSHFIELD, GA
    ALPERT, BS
    PULLIAM, DA
    SOMES, GW
    WILSON, DK
    PEDIATRICS, 1994, 94 (02) : 180 - 184
  • [33] INDEPENDENCE OF BLOOD-PRESSURE RESPONSE TO EXERCISE AND AMBULATORY BLOOD-PRESSURE VALUES IN ESSENTIAL-HYPERTENSION
    KARPANOU, EA
    VYSSOULIS, GP
    MICHAELIDES, AP
    KOUREMETIS, MT
    TOUTOUZAS, PK
    AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1994, 8 (05): : 278 - 281
  • [34] AMBULATORY BLOOD-PRESSURE MONITORING IN SECONDARY HYPERTENSION
    PADFIELD, PL
    STEWART, MJ
    JOURNAL OF HYPERTENSION, 1991, 9 : S69 - S71
  • [35] Ambulatory blood pressure reproducibility and application of the method in a healthy Finnish cohort
    Hietanen, E
    WendelinSaarenhovi, M
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1996, 56 (05) : 471 - 480
  • [36] Reproducibility of ambulatory blood pressure measurements in essential hypertension
    Zakopoulos, NA
    Nanas, SN
    Lekakis, JP
    Vemmos, KN
    Kotsis, VT
    Pitiriga, VC
    Stamatelopoulos, SF
    Moulopoulos, SD
    BLOOD PRESSURE MONITORING, 2001, 6 (01) : 41 - 45
  • [37] Reproducibility of ambulatory blood pressure monitoring results in pregnancy
    Livi, R
    Teghini, L
    Parretti, E
    Detti, L
    Mello, G
    AMERICAN JOURNAL OF HYPERTENSION, 1998, 11 (07) : 852 - 855
  • [38] Reproducibility of ambulatory blood pressure monitoring in arterial hypertension
    Ribera, L
    Sobrino, J
    Pladevall, M
    Felip, A
    Soler, J
    Modol, J
    Plana, J
    Comes, L
    Adrian, MJ
    Coca, A
    AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (04) : 148A - 148A
  • [39] Reproducibility of home and ambulatory blood pressure in children and adolescents
    Stergiou, GS
    Alamara, CV
    Salgami, EV
    Vaindirlis, IN
    Dacou-Voutetakis, C
    Mountokalakis, TD
    AMERICAN JOURNAL OF HYPERTENSION, 2004, 17 (05) : 57A - 57A
  • [40] Reproducibility of ambulatory blood pressure monitoring in hemodialysis patients
    Peixoto, AJ
    Santos, SFF
    Mendes, RB
    Crowley, ST
    Maldonado, R
    Orias, M
    Mansoor, GA
    White, WB
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2000, 36 (05) : 983 - 990