LONG-TERM REPRODUCIBILITY, OF AMBULATORY BLOOD-PRESSURE

被引:0
作者
MANSOOR, GA [1 ]
MCCABE, EJ [1 ]
WHITE, WB [1 ]
机构
[1] UNIV CONNECTICUT,SCH MED,DEPT MED,HYPERTENS & VASC DIS SECT,FARMINGTON,CT 06032
关键词
AMBULATORY BLOOD PRESSURE; REPRODUCIBILITY;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: To compare the reproducibility of ambulatory and office blood pressure readings in established hypertensive subjects when studies are repeated at extended time intervals. Subjects: Twenty-five hypertensive patients (office diastolic blood pressure greater than or equal to 90 mmHg) who were off antihypertensive therapy for at least 4 weeks and had repeat office and ambulatory blood pressures at least 3 months apart under similar study conditions. Methods: On the same day, patients underwent office blood pressure readings measured by mercury column sphygmomanometry and then by ambulatory blood pressure monitoring. Ambulatory blood pressure monitoring was done for 24 h, and awake and sleep periods were divided according to a diary kept by each patient. A second study was performed in an identical manner at a mean +/- SD interval of 23 +/- 24 months (range 3-80, median 15). The agreement between studies was assessed by correlation coefficients, coefficients of variation and standard deviation of the differences (SDD). Results: There were no significant differences in office, 24-h, awake and sleep mean blood pressures between the two studies. Mean 24-h systolic and diastolic blood pressures were 16 and 14 mmHg lower, respectively, than office blood pressure values. Correlation coefficients were significantly higher for 24-h ambulatory blood pressure than office blood pressure, whereas the SDD between visits was significantly lower for 24-h ambulatory blood pressure than office blood pressure. Conclusions: These data demonstrate that long-term reproducibility of ambulatory blood pressure is superior to that for office measurement. One implication of this finding is that, in long-term clinical pharmacology trials utilizing ambulatory blood pressure, fewer subjects would be required than for studies that used office blood pressure end-points.
引用
收藏
页码:703 / 708
页数:6
相关论文
共 17 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
CLEMENT DL, J HYPERTENS S8, V9, pS51
[3]  
CONWAY J, 1988, J HYPERTENS, V6, P111
[4]   REPRODUCIBILITY OF BLOOD-PRESSURE VALUES IN NORMOTENSIVE SUBJECTS [J].
DRAYER, JIM ;
WEBER, MA .
CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1985, 7 (2-3) :417-422
[5]   REPRODUCIBILITY OF AMBULATORY AND CLINIC BLOOD-PRESSURE MEASUREMENTS IN ELDERLY HYPERTENSIVE SUBJECTS [J].
FOTHERBY, MD ;
POTTER, JF .
JOURNAL OF HYPERTENSION, 1993, 11 (05) :573-579
[6]   LONG-TERM REPRODUCIBILITY AND EVALUATION OF SEASONAL INFLUENCE ON BLOOD-PRESSURE MONITORING [J].
GIACONI, S ;
PALOMBO, C ;
GENOVESIEBERT, A ;
MARABOTTI, C ;
VOLTERRANI, D ;
GHIONE, S .
JOURNAL OF HYPERTENSION, 1988, 6 :S64-S66
[7]   THE REPRODUCIBILITY OF AVERAGE AMBULATORY, HOME, AND CLINIC PRESSURES [J].
JAMES, GD ;
PICKERING, TG ;
YEE, LS ;
HARSHFIELD, GA ;
RIVA, S ;
LARAGH, JH .
HYPERTENSION, 1988, 11 (06) :545-549
[8]   LIMITED REPRODUCIBILITY OF HOURLY BLOOD-PRESSURE VALUES OBTAINED BY AMBULATORY BLOOD-PRESSURE MONITORING - IMPLICATIONS FOR STUDIES ON ANTIHYPERTENSIVE DRUGS [J].
MANCIA, G ;
OMBONI, S ;
PARATI, G ;
TRAZZI, S ;
MUTTI, E .
JOURNAL OF HYPERTENSION, 1992, 10 (12) :1531-1535
[9]   AMBULANT BLOOD-PRESSURE - REPRODUCIBILITY AND THE ASSESSMENT OF INTERVENTIONS [J].
MANN, S ;
CRAIG, MWM ;
BALASUBRAMANIAN, V ;
CASHMAN, PMM ;
RAFTERY, EB .
CLINICAL SCIENCE, 1980, 59 (06) :497-500
[10]   HOW COMMON IS WHITE COAT HYPERTENSION [J].
PICKERING, TG ;
JAMES, GD ;
BODDIE, C ;
HARSHFIELD, GA ;
BLANK, S ;
LARAGH, JH .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1988, 259 (02) :225-228