MEASUREMENT OF STROKE VOLUME AND CARDIAC-OUTPUT WITHIN A SINGLE-BREATH HOLD WITH ECHO-PLANAR MR-IMAGING

被引:18
作者
HUNTER, GJ [1 ]
HAMBERG, LM [1 ]
WEISSKOFF, RM [1 ]
HALPERN, EF [1 ]
BRADY, TJ [1 ]
机构
[1] MASSACHUSETTS GEN HOSP,CTR IMAGING & PHARMACEUT RES,BOSTON,MA 02129
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1994年 / 4卷 / 01期
关键词
HEART; EJECTION FRACTION; FUNCTION; MR; VENTRICLES; VOLUME; RAPID IMAGING;
D O I
10.1002/jmri.1880040112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The measurement of cardiac output and ejection fraction is useful in the treatment of diverse cardiac and cardiopulmonary disease states. Although several techniques are available for accurate measurement of left ventricular parameters, assessment of the right ventricle is less well represented. No single method is overwhelmingly superior, each having different strengths and weaknesses. In the present study, the applicability of an echo-planar magnetic resonance (MR) imaging method in which a complete volumetric measurement of the right and left ventricles may be obtained during 12 heartbeats is demonstrated. This rapidity permits imaging during a 15-second breath hold. The authors show in 12 volunteers that breath-hold echo-planar volume measurements of both ventricles were consistent with results obtained with conventional MR imaging methods.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 35 条
[21]   COMPARISON OF BREATH-HOLD FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES FOR T2-WEIGHTED MR-IMAGING OF LIVER-LESIONS [J].
RYDBERG, JN ;
LOMAS, DJ ;
COAKLEY, KJ ;
HOUGH, DM ;
EHMAN, RL ;
RIEDERER, SJ .
RADIOLOGY, 1995, 194 (02) :431-437
[22]   Hemorrhagic and nonhemorrhagic stroke: Diagnosis with diffusion-weighted and T2-weighted echo-planar MR imaging [J].
Ebisu, T ;
Tanaka, C ;
Umeda, M ;
Kitamura, M ;
Fukunaga, M ;
Aoki, I ;
Sato, H ;
Higuchi, T ;
Naruse, S ;
Horikawa, Y ;
Ueda, S .
RADIOLOGY, 1997, 203 (03) :823-828
[23]   Measurement of the distribution volume of gadopentetate dimeglumine at echo-planar MR imaging to quantify myocardial infarction:: Comparison with 99mTc-DTPA autoradiography in rats [J].
Arheden, H ;
Saeed, M ;
Higgins, CB ;
Gao, DW ;
Bremerich, J ;
Wyttenbach, R ;
Dae, MW ;
Wendland, MF .
RADIOLOGY, 1999, 211 (03) :698-708
[24]   Reproducibility of left ventricular mass measurement using a half-fourier black-blood single-shot fast spin-echo sequence within a single breath hold: Comparison with a conventional multiple breath-hold gradient echo technique segmented in patients [J].
Vignaux, O ;
Duboc, D ;
Coste, J ;
Argaud, C ;
Carlier, P ;
Le Roux, P ;
Weber, S ;
Legmann, P .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (06) :654-660
[25]   SINGLE-BREATH-HOLD VENOUS OR ARTERIAL FLOW SUPPRESSED PULMONARY VASCULAR MR-IMAGING WITH PHASED-ARRAY COILS [J].
FOO, TKF ;
MACFALL, JR ;
SOSTMAN, HD ;
HAYES, CE .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04) :611-616
[26]   MR imaging of the liver: Comparison between single-shot echo-planar and half-Fourier rapid acquisition with relaxation enhancement sequences [J].
Yamashita, Y ;
Tang, Y ;
Namimoto, T ;
Mitsuzaki, K ;
Takahashi, M .
RADIOLOGY, 1998, 207 (02) :331-337
[27]   Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients [J].
Ichikawa, T ;
Haradome, H ;
Hachiya, J ;
Nitatori, T ;
Araki, T .
ABDOMINAL IMAGING, 1999, 24 (05) :456-461
[28]   Measurement of the apparent diffusion coefficient in intraductal mucin-producing tumor of the pancreas by diffusion-weighted echo-planar MR imaging [J].
Irie, H ;
Honda, H ;
Kuroiwa, T ;
Yoshimitsu, K ;
Aibe, H ;
Shinozaki, K ;
Masuda, K .
ABDOMINAL IMAGING, 2002, 27 (01) :82-87
[29]   Clinically relevant rat model for testing BOLD functional MR imaging techniques by using single-shot echo-planar imaging at 1.5 T [J].
Morton, DW ;
Maravilla, KR ;
Meno, JR ;
Winn, HR .
RADIOLOGY, 2001, 218 (02) :598-601
[30]   Evaluation of liver diffusion isotropy and characterization of focal hepatic lesions with two single-shot echo-planar MR imaging sequences: Prospective study in 66 patients [J].
Taouli, B ;
Vilgrain, V ;
Dumont, E ;
Daire, JL ;
Fan, B ;
Menu, Y .
RADIOLOGY, 2003, 226 (01) :71-78