A COMPRESSION-LOADED DOUBLE CANTILEVER BEAM SPECIMEN

被引:11
作者
GONZALEZ, AC
PANTANO, CG
机构
[1] Department of Materials Science and Engineering, The Pennsylvania State University, University Park, Pennsylvania
关键词
crack growth; double cantilever beams; fractography; load; stress;
D O I
10.1111/j.1151-2916.1990.tb07629.x
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In crack propagation studies, double cantilever beam specimens are typically loaded in tension or by an applied moment. A method of compression loading is described in which the stress intensity KI decreases with crack length. This new arrangement offers added crack stability over other techniques, as well as a convenient method of loading. Copyright © 1990, Wiley Blackwell. All rights reserved
引用
收藏
页码:2534 / 2535
页数:2
相关论文
共 6 条
[1]  
BEER FP, 1972, VECTOR MECHANICS ENG, pCH3
[2]   CRACK-PROPAGATION STUDIES IN BRITTLE MATERIALS [J].
FREIMAN, SW ;
MULVILLE, DR ;
MAST, PW .
JOURNAL OF MATERIALS SCIENCE, 1973, 8 (11) :1527-1533
[3]  
FREIMAN SW, 1983, FRACTURE MECHANICS C, V6, P27
[4]   EFFECT OF CORROSION PROCESSES ON SUBCRITICAL CRACK-GROWTH IN GLASS [J].
SIMMONS, CJ ;
FREIMAN, SW .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1981, 64 (11) :683-686
[5]   FRACTURE OF GLASS IN VACUUM [J].
WIEDERHORN, SM ;
DINESS, AM ;
HEUER, AH .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1974, 57 (08) :336-341
[6]  
WIEDERHORN SM, 1974, FRACTURE MECHANICS C, V2, P613