Relationship between self-priming and hydraulic behavior in Venturi Scrubber

被引:4
|
作者
Horiguchi, Naoki [1 ,2 ]
Yoshida, Hiroyuki [2 ]
Kaneko, Akiko [1 ]
Abe, Yutaka [1 ]
机构
[1] Univ Tsukuba, Dept Engn Mech & Energy, Grad Sch Syst & Informat Engn, 1-1-1 Tennoudai, Tsukuba, Ibaraki 3058573, Japan
[2] Japan Atom Energy Agcy, Res Grp Accid Progress Anal, Nucl Decommissioning Technol Unit, Nucl Sci & Engn Ctr,Sect Nucl Sci Res, Tokai, Ibaraki 3191195, Japan
来源
MECHANICAL ENGINEERING JOURNAL | 2014年 / 1卷 / 04期
关键词
Venturi scrubber; Visualized observation; Filtered venting; Self-priming; Hydraulic behavior;
D O I
10.1299/mej.2014tep0026
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
As revealed by Fukushima Daiichi nuclear disaster, countermeasures against severe accident in nuclear power plants are an urgent need. In particular, from the viewpoint of protecting a containment and suppressing the diffusion of radioactive materials, it is important to develop the device which allows a filtered venting of contaminated high pressure gas. In the filtered venting system that used in European reactors, so called Multi Venturi Scrubbers System is used to realize filtered venting without any power supply (Lindau, 1988) (Rust, et al., 1995). The system operates with any power supply and high pressure gas filled in the containment This system is able to define to be composed of Venturi Scrubbers (VS) and a bubble column. In the VS, scrubbing of contaminated gas is promoted by both gas releases through a submerged VS and gas-liquid contact with splay flow formed by liquid suctioned through a hole provided by the pressure difference between inner and outer parts of a throat part of the VS. This type of the VS is called self-priming ones. However, the scrubbing mechanism of the self-priming VS including effects of gas mass flow rate and shape of the VS are understood insufficiently in the previous studies. In this study, to understand the VS operation characteristics for the filtered venting, we discussed the mechanisms of the self-priming phenomena and the hydraulic behavior in the VS. In this paper, we conducted a visualized observation of the hydraulic behavior in the VS and measured liquid flow rate of the self-primming. As a result, it is shown that there is the possibility that the VS decontamination performance falls low level with no self-priming.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] RESEARCH AND DEVELOPMENT OF SELF-PRIMING VENTURI SCRUBBER FOR FILTER VENTING: PRELIMINARY ANALYSIS AND OBSERVATION OF HYDRAULIC BEHAVIOR IN VENTURI SCRUBBER
    Horiguchi, Naoki
    Yoshida, Hiroyuki
    Uesawa, Shin-ichiro
    Kaneko, Akiko
    Abe, Yutaka
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 6, 2014,
  • [2] Study of iodine removal efficiency in self-priming venturi scrubber
    Ali, Majid
    Yan, Changqi
    Sun, Zhongning
    Gu, Haifeng
    Wang, Junlong
    ANNALS OF NUCLEAR ENERGY, 2013, 57 : 263 - 268
  • [3] Numerical study on the performance of Venturi scrubber in self-priming mode
    Lee, J. W.
    Kim, W. S.
    Kim, H. S.
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON TURBULENCE HEAT AND MASS TRANSFER (THMT-15), 2015, : 891 - 894
  • [4] Study of hydrodynamics and iodine removal by self-priming venturi scrubber
    Ahad, Jawaria
    Rizwan, Talha
    Farooq, Amjad
    Waheed, Khalid
    Ahmad, Masroor
    Qureshi, Kamran Rasheed
    Siddique, Waseem
    Irfan, Naseem
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (01) : 169 - 179
  • [5] Injection performance and influencing factors in self-priming Venturi scrubber
    Zhou, Yanmin
    Sun, Zhongning
    Gu, Haifeng
    Miao, Zhuang
    Huagong Xuebao/CIESC Journal, 2015, 66 (01): : 99 - 104
  • [6] Study of Pressure Drop Model for Self-Priming Venturi Scrubber
    Ali, Majid
    Yan ChangQi
    Sun Zhongning
    Gu Hai Feng
    Wang Meng
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [7] Experimental study of iodine removal efficiency in self-priming venturi scrubber
    Gulhane, N. P.
    Landge, A. D.
    Shukla, D. S.
    Kale, S. S.
    ANNALS OF NUCLEAR ENERGY, 2015, 78 : 152 - 159
  • [8] Research on injection characteristics of venturi scrubber worked in self-priming mode
    Zhou, Yan-Min
    Sun, Zhong-Ning
    Gu, Hai-Feng
    Miao, Zhuang
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2015, 49 (06): : 1075 - 1079
  • [9] OPERATING RESULTS AND AEROSOL DEPOSITION OF A VENTURI SCRUBBER IN SELF-PRIMING OPERATION
    MAYINGER, F
    LEHNER, M
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 1995, 34 (03) : 283 - 288
  • [10] Aerosol separation efficiency of a venturi scrubber working in self-priming mode
    Lehner, M