EXPERT SYSTEMS FOR MULTIVARIATE CALIBRATION, TRENDSETTERS FOR THE WIDE-SPREAD USE OF CHEMOMETRICS

被引:8
作者
GERRITSEN, M [1 ]
VANLEEUWEN, JA [1 ]
VANDEGINSTE, BGM [1 ]
BUYDENS, L [1 ]
KATEMAN, G [1 ]
机构
[1] CATHOLIC UNIV NIJMEGEN,DEPT ANALYT CHEM,6525 ED NIJMEGEN,NETHERLANDS
关键词
D O I
10.1016/0169-7439(92)85007-P
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Chemometrics is less applied in practice than desirable. One of the reasons is the lack of software tools that allow an easy application of chemometrics by non-experts. A possible solution to this problem is the integration of expert systems with software for data analysis. This is illustrated with an example on high-performance liquid chromatography-ultraviolet data analysis. The integration of expert know[edge with chemometrical software will probably become an important future trend in chemometrical research as it is not restricted to multivariate data analysis.
引用
收藏
页码:171 / 184
页数:14
相关论文
共 35 条
[1]  
GAMMP H, 1987, ANAL CHIM ACTA, V193, P287
[2]  
Gemperline P.J., 1989, J CHEMOMETR, V3, P549, DOI DOI 10.1002/cem.1180030404
[3]   A PRIORI ESTIMATES OF THE ELUTION PROFILES OF THE PURE COMPONENTS IN OVERLAPPED LIQUID-CHROMATOGRAPHY PEAKS USING TARGET FACTOR-ANALYSIS [J].
GEMPERLINE, PJ .
JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 1984, 24 (04) :206-212
[4]   CONDITIONS FOR DETECTING OVERLAPPED PEAKS WITH PRINCIPAL COMPONENT ANALYSIS IN HYPHENATED CHROMATOGRAPHIC METHODS [J].
GEMPERLINE, PJ ;
HAMILTON, JC .
ANALYTICAL CHEMISTRY, 1989, 61 (20) :2240-2243
[5]   TARGET TRANSFORMATION FACTOR-ANALYSIS WITH LINEAR INEQUALITY CONSTRAINTS APPLIED TO SPECTROSCOPIC CHROMATOGRAPHIC DATA [J].
GEMPERLINE, PJ .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :2656-2663
[6]   REALISTIC SIMULATIONS OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ULTRAVIOLET DATA FOR THE EVALUATION OF MULTIVARIATE TECHNIQUES [J].
GERRITSEN, MJP ;
FABER, NM ;
VANRIJN, M ;
VANDEGINSTE, BGM ;
KATEMAN, G .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1992, 12 (03) :257-268
[7]  
Hamilton J.C., 1990, J CHEMOMETR, V4, P1, DOI 10.1002/cem.1180040103
[8]   SIMULTANEOUS MULTICOMPONENT RANK ANNIHILATION AND APPLICATIONS TO MULTICOMPONENT FLUORESCENT DATA ACQUIRED BY THE VIDEO FLUOROMETER [J].
HO, CN ;
CHRISTIAN, GD ;
DAVIDSON, ER .
ANALYTICAL CHEMISTRY, 1981, 53 (01) :92-98
[9]   APPLICATION OF METHOD OF RANK ANNIHILATION TO QUANTITATIVE-ANALYSES OF MULTICOMPONENT FLUORESCENCE DATA FROM VIDEO FLUOROMETER [J].
HO, CN ;
CHRISTIAN, GD ;
DAVIDSON, ER .
ANALYTICAL CHEMISTRY, 1978, 50 (08) :1108-1113
[10]   PEAK PURITY CONTROL IN LIQUID-CHROMATOGRAPHY WITH PHOTODIODE-ARRAY DETECTION BY A FIXED SIZE MOVING WINDOW EVOLVING FACTOR-ANALYSIS [J].
KELLER, HR ;
MASSART, DL .
ANALYTICA CHIMICA ACTA, 1991, 246 (02) :379-390