Chest Circumference as a Predictive Parameter of Computed Tomography Coronary Angiography Radiation Doses from Dual-Source Computed Tomography

被引:5
作者
Sagsoz, M. Erdem [1 ]
Bayraktutan, Ummugulsum [2 ]
Ogul, Hayri [2 ]
Kantarci, Mecit [2 ]
机构
[1] Ataturk Univ, Sch Med, Dept Biophys, Erzurum, Turkey
[2] Ataturk Univ, Sch Med, Dept Radiol, Erzurum, Turkey
关键词
Breast; Cardiac; DSCT; Radiation dose;
D O I
10.5152/eajm.2013.07
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Our aim in this study was to determine the relationship between chest circumference and the radiation doses received by breast tissues during Dual-Source Computed Tomography (DSCT) cardiac scans. Materials and Methods: Routine cardiac DSCT examinations with similar exposure lengths were applied to 30 female patients. The scanogram image, multi-slice helical scan x-ray tube voltage and anode-cathode current were adjusted automatically according to attenuation for each patient during the scanogram acquisition. The standard protocol was otherwise applied to all patients. The 30 patients had an average weight of 67.8 +/- 15.3 kg, and the average length of the scanned region was 278.0 +/- 11.6 mm. Radiation doses were calculated from the dose-length product (DLP) and the computed tomography dose index (CTDI) scanner data values. The correlations between radiation dose and chest circumference were investigated. The level of significance was set at p<0.05. Results: For routine cardiac DSCT scans, the average values were as follows: total DLP: 715.54 +/- 317.01 mGycm, CTDIvol: 40.79 +/- 19.41 mGy, and effective dose (ED): 17.89 +/- 7.93 mSv. The chest circumference of patients correlates well with their radiation exposure (p<0.01). Conclusion: The distribution of different tissues throughout the human body may vary among races and genders. Because of this, many researchers use body mass index (BMI) to set image quality and predict the radiation dose distribution from general computed tomography (CT) examinations. Additional anthropomorphic phantom studies should be conducted to determine more accurate conversion factors and, hence, better ED predictions.
引用
收藏
页码:43 / 46
页数:4
相关论文
共 20 条
[1]   Direct Quantification of Breast Dose During Coronary CT Angiography and Evaluation of Dose Reduction Strategies [J].
Abadi, Sobhi ;
Mehrez, Hatem ;
Ursani, Ali ;
Parker, Mark ;
Paul, Narinder .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (02) :W152-W158
[2]   Radiation dose of cardiac dual-source CT: The effect of tailoring the protocol to patient-specific parameters [J].
Alkadhi, Hatem ;
Stolzmann, Paul ;
Scheffel, Hans ;
Desbiolles, Lotus ;
Baumueller, Stephan ;
Plass, Andre ;
Genoni, Michele ;
Marincek, Borut ;
Leschka, Sebastian .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) :385-391
[3]   X-ray induced DNA double-strand breaks in coronary CT angiography: Comparison of sequential, low-pitch helical and high-pitch helical data acquisition [J].
Brand, Michael ;
Sommer, Matthias ;
Achenbach, Stephan ;
Anders, Katharina ;
Lell, Michael ;
Loebrich, Markus ;
Uder, Michael ;
Kuefner, Michael A. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) :E357-E362
[4]   Gender influence on dose saving allowed by prospective-triggered 64-slice multidetector computed tomography coronary angiography as compared with retrospective-gated mode [J].
Esposito, Antonio ;
De Cobelli, Francesco ;
Colantoni, Caterina ;
Perseghin, Gianluca ;
del Vecchio, Antonella ;
Canu, Tamara ;
Calandrino, Riccardo ;
Del Maschio, Alessandro .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 158 (02) :253-259
[5]   Radiation dose reduction to breast and thyroid during MDCT:: Effectiveness of an in-plane bismuth shield [J].
Hohl, C ;
Wildberger, JE ;
Süss, C ;
Thomas, C ;
Mühlenbruch, G ;
Schmidt, T ;
Honnef, D ;
Günther, RW ;
Mahnken, AH .
ACTA RADIOLOGICA, 2006, 47 (06) :562-567
[6]  
Huda W, 2008, RADIOLOGY, V248, P321, DOI 10.1148/radiol.2481080042
[7]   Radiation dose from contemporary cardiothoracic multidetector CT Protocols with an anthropomorphic female phantom: Implications for cancer induction [J].
Hurwitz, Lynne M. ;
Reiman, Robert E. ;
Yoshizumi, Terry T. ;
Goodman, Philip C. ;
Toncheva, Greta ;
Nguyen, Giao ;
Lowry, Carolyn .
RADIOLOGY, 2007, 245 (03) :742-750
[8]   Dual-source computed tomography: Estimation of radiation exposure of ECG-gated and ECG-triggered coronary angiography [J].
Ketelsen, Dominik ;
Thomas, Christoph ;
Werner, Matthias ;
Luetkhoff, Marie H. ;
Buchgeister, Markus ;
Tsiflikas, Ilias ;
Reimann, Anja ;
Burgstahler, Christof ;
Brodoefel, Harald ;
Kopp, Andreas F. ;
Claussen, Claus D. ;
Heuschmid, Martin .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 73 (02) :274-279
[9]   Assessment of radiation exposure on a dual-source computed tomography-scanner performing coronary computed tomography-angiography [J].
Kirchhoff, S. ;
Herzog, P. ;
Johnson, T. ;
Boehm, H. ;
Nikolaou, K. ;
Reiser, M. F. ;
Becker, C. H. .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (03) :E182-E186
[10]   High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography [J].
Mollet, NR ;
Cademartiri, F ;
van Mieghem, CAG ;
Runza, G ;
McFadden, EP ;
Baks, T ;
Serruys, PW ;
Krestin, GP ;
de Feyter, PJ .
CIRCULATION, 2005, 112 (15) :2318-2323