FERROMAGNETISM AND MAGNETIC-RESONANCE ARTIFACTS OF PLATINUM EMBOLIZATION MICROCOILS

被引:27
|
作者
MARSHALL, MW [1 ]
TEITELBAUM, GP [1 ]
KIM, HS [1 ]
DEVEIKIS, J [1 ]
机构
[1] UNIV SO CALIF,LOS ANGELES CTY MED CTR,DEPT RADIOL,1200 N STATE ST,LOS ANGELES,CA 90033
关键词
MAGNETIC RESONANCE IMAGING; ARTIFACTS; SAFETY; EMBOLIZATION; COILS; PLATINUM;
D O I
10.1007/BF02577720
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We performed in vitro tests of ferromagnetism of platinum microcoils of two manufacturers. In addition, we performed in vitro magnetic resonance imaging (MRI) on these two devices to determine their levels of magnetic susceptibility artifact production. We found that both devices were nonferromagnetic and produced a very low level of artifact during MRI. In vivo MRI of a dog and 2 patients having previous placement of platinum microcoils was performed without coil migration or significant artifact production. Platinum microcoils are highly MR-compatible.
引用
收藏
页码:163 / 166
页数:4
相关论文
共 50 条
  • [31] SYNTHESIS AND NUCLEAR MAGNETIC-RESONANCE SPECTRA OF PLATINUM COMPOUNDS WITH THIOUREA DERIVATIVES
    ROCHON, FD
    BARIYANGA, J
    KONG, PC
    CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1985, 63 (09): : 2425 - 2429
  • [32] PT-195 MAGNETIC-RESONANCE SPECTRA OF SOME PLATINUM(II) AND PLATINUM(IV) COMPLEXES
    PESEK, JJ
    MASON, WR
    JOURNAL OF MAGNETIC RESONANCE, 1977, 25 (03) : 519 - 529
  • [33] Development of low field nuclear magnetic resonance microcoils
    Goloshevsky, AG
    Walton, JH
    Shutov, MV
    de Ropp, JS
    Collins, SD
    McCarthy, MJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (02): : 024101 - 1
  • [34] Microcoils on structured silicon substrates for magnetic resonance detection
    Li, Yan
    Ahmad, Munir M.
    Hand, Jeff W.
    Syms, Richard R. A.
    Gilderdale, David
    Collins, David J.
    Young, Ian R.
    IEEE SENSORS JOURNAL, 2007, 7 (9-10) : 1362 - 1369
  • [35] REDUCTION OF ARTIFACTS IN MAGNETIC-RESONANCE IMAGES BY USING OPTIMIZED MATERIALS FOR DIAGNOSTIC DEVICES AND IMPLANTS
    FRITZSCHE, S
    THULL, R
    HAASE, A
    BIOMEDIZINISCHE TECHNIK, 1995, 40 (1-2): : 29 - 33
  • [36] REDUCTION OF ARTIFACTS IN MAGNETIC-RESONANCE IMAGES BY USING OPTIMIZED MATERIALS FOR DIAGNOSTIC DEVICES AND IMPLANTS
    FRITZSCHE, S
    THULL, R
    HAASE, A
    BIOMEDIZINISCHE TECHNIK, 1994, 39 (03): : 42 - 46
  • [37] THE USE OF MAGNETIC-RESONANCE IMAGING WITH MAGNETIC-RESONANCE SPECTROSCOPY IN THE STUDY OF MEDULLOBLASTOMA
    WHELAN, HT
    STROTHER, D
    LI, S
    ANNALS OF NEUROLOGY, 1989, 26 (03) : 455 - 455
  • [38] Artifacts in magnetic resonance angiography
    Brunereau, L
    Bousson, V
    Arrive, L
    Levy, C
    Marsot-Dupuch, K
    Tubiana, JM
    JOURNAL DE RADIOLOGIE, 1998, 79 (09): : 849 - 859
  • [39] Artifacts in Magnetic Resonance Imaging
    Krupa, Katarzyna
    Bekiesinska-Figatowska, Monika
    POLISH JOURNAL OF RADIOLOGY, 2015, 80 : 93 - 106
  • [40] MAGNETIC-RESONANCE STUDIES OF PROPENE ADSORPTION ON ALUMINA-SUPPORTED PLATINUM SURFACES
    GRIFFITHS, JM
    BELL, AT
    REIMER, JA
    JOURNAL OF PHYSICAL CHEMISTRY, 1994, 98 (07): : 1918 - 1925