FERROMAGNETISM AND MAGNETIC-RESONANCE ARTIFACTS OF PLATINUM EMBOLIZATION MICROCOILS

被引:27
|
作者
MARSHALL, MW [1 ]
TEITELBAUM, GP [1 ]
KIM, HS [1 ]
DEVEIKIS, J [1 ]
机构
[1] UNIV SO CALIF,LOS ANGELES CTY MED CTR,DEPT RADIOL,1200 N STATE ST,LOS ANGELES,CA 90033
关键词
MAGNETIC RESONANCE IMAGING; ARTIFACTS; SAFETY; EMBOLIZATION; COILS; PLATINUM;
D O I
10.1007/BF02577720
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We performed in vitro tests of ferromagnetism of platinum microcoils of two manufacturers. In addition, we performed in vitro magnetic resonance imaging (MRI) on these two devices to determine their levels of magnetic susceptibility artifact production. We found that both devices were nonferromagnetic and produced a very low level of artifact during MRI. In vivo MRI of a dog and 2 patients having previous placement of platinum microcoils was performed without coil migration or significant artifact production. Platinum microcoils are highly MR-compatible.
引用
收藏
页码:163 / 166
页数:4
相关论文
共 50 条
  • [21] MAGNETIC-RESONANCE TOMOGRAPHY AND MAGNETIC-RESONANCE ANGIOGRAPHY OF LYMPHANGIOMATOSIS
    VOGL, TJ
    HAMMERSTINGL, R
    SCHNELL, B
    KLEIN, C
    HAUSER, M
    PFLUGER, T
    LISSNER, J
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 157 (04): : 414 - 419
  • [22] ARTIFACTS DUE TO RESIDUAL MAGNETIZATION IN 3-DIMENSIONAL MAGNETIC-RESONANCE IMAGING
    WOOD, ML
    RUNGE, VM
    MEDICAL PHYSICS, 1988, 15 (06) : 825 - 831
  • [23] ARTIFACTS, VARIANTS, AND FACTORS DEGRADING IMAGE QUALITY IN PEDIATRIC MAGNETIC-RESONANCE IMAGING
    RINGERTZ, HG
    BRASCH, RC
    GOODING, CA
    PEDIATRIC RADIOLOGY, 1985, 15 (03) : 173 - 178
  • [24] MAGNETIC-RESONANCE
    EHMAN, RL
    BRYAN, RN
    CRUES, JV
    HRICAK, H
    KRESSEL, HY
    LENKINSKI, RE
    MITCHELL, DG
    MOSELEY, ME
    RIEDERER, SJ
    ROSS, JR
    RADIOLOGY, 1991, 178 (03) : 907 - 910
  • [25] MAGNETIC-RESONANCE
    BUONANNO, F
    CURRENT OPINION IN NEUROLOGY AND NEUROSURGERY, 1988, 1 (06): : 977 - 984
  • [26] MAGNETIC-RESONANCE
    DAMADIAN, R
    HOSPITALS, 1984, 58 (15): : 14 - &
  • [27] MAGNETIC-RESONANCE
    EHMAN, RL
    ANDERSON, MW
    CRUES, JV
    LENKINSKI, RE
    MITCHELL, DG
    PETTIGREW, RI
    RIEDERER, SJ
    ROSS, JR
    RADIOLOGY, 1995, 194 (03) : 933 - 940
  • [28] MAGNETIC-RESONANCE
    BRYAN, RN
    EHMAN, RL
    HRICAK, H
    KRESSEL, HY
    MAWAD, MM
    RADIOLOGY, 1990, 174 (03) : 913 - 915
  • [29] NUCLEAR MAGNETIC-RESONANCE ON ORIENTED PLATINUM-195M IN IRON
    BACON, F
    SHIRLEY, DA
    KAINDL, G
    MAHNKE, HE
    PHYSICAL REVIEW LETTERS, 1972, 28 (12) : 720 - &
  • [30] MAGNETIC-RESONANCE OF A SMALL PLATINUM PARTICLE USING AN INTEGRATED DC SQUID
    NARASIMHAN, LR
    TAKIGAWA, M
    KETCHEN, MB
    APPLIED PHYSICS LETTERS, 1994, 65 (10) : 1305 - 1307