Analysis of a Theoretical Model for Anisotropic Enzyme Membranes Application to Enzyme Electrodes

被引:1
|
作者
Pedersen, Henrik [1 ]
Chotani, Gopal K. [1 ]
机构
[1] Rutgers State Univ, Coll Engn, Dept Chem & Biochem Engn, Piscataway, NJ 08854 USA
关键词
Anisotropic membrane electrodes; theoretical model for; membrane electrode; electrode; enzyme electrode;
D O I
10.1007/BF02798281
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A theoretical model of diffusion and reaction in an anisotropic enzyme membrane is presented with particular emphasis on the application of such membranes in enzyme electrodes. The dynamic response of systems in which the kinetics are linear, which comprises the practical operating regime for enzyme electrodes in analysis, is investigated via an analytic solution of the governing differential equations. The response is presented as a function of a single dimensionless group, mu, that is the membrane modulus.
引用
收藏
页码:309 / 317
页数:9
相关论文
共 50 条
  • [1] ASYMMETRICAL COUPLING OF ENZYMATIC SYSTEMS ON COLLAGEN MEMBRANES APPLICATION TO MULTI-ENZYME ELECTRODES
    COULET, PR
    BERTRAND, C
    ANALYTICAL LETTERS, 1979, 12 (06) : 581 - 587
  • [2] INTERNAL MEMBRANES AND LAMINATES FOR ADAPTATION OF AMPEROMETRIC ENZYME ELECTRODES TO DIRECT BIOFLUID ANALYSIS
    DESAI, MA
    GHOSH, S
    CRUMP, PW
    BENMAKROHA, Y
    VADGAMA, PM
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1993, 53 : 53 - 60
  • [3] Computational modelling of amperometric enzyme electrodes with selective and perforated membranes
    Baronas, Romas
    Ivanauskas, Feliksas
    Kulys, Juozas
    COMPUTATION IN MODERN SCIENCE AND ENGINEERING VOL 2, PTS A AND B, 2007, 2 : 457 - +
  • [4] MATHEMATICAL-MODELING OF AMPEROMETRIC ENZYME ELECTRODES WITH PERFORATED MEMBRANES
    SCHULMEISTER, T
    PFEIFFER, D
    BIOSENSORS & BIOELECTRONICS, 1993, 8 (02) : 75 - 79
  • [5] Enzyme electrodes with enzyme immobilised by Solgel technique
    Przybyt, M
    Bialkowska, B
    FRONTIERS OF MULTIFUNCTIONAL NANOSYSTEMS, 2002, 57 : 91 - 108
  • [6] Mediated enzyme electrodes
    Boukoureshtlieva, R. I.
    Hristov, S. M.
    Milusheva, Y. D.
    Atanassov, P. B.
    Kaisheva, A. R.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2011, 43 (01): : 81 - 87
  • [7] The application of alkanethiol self-assembled monolayers to enzyme electrodes
    Gooding, JJ
    Hibbert, DB
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (08) : 525 - 533
  • [8] Organic phase enzyme electrodes
    Sanchez-Paniagua Lopez, M.
    Lopez-Cabarcos, E.
    Lopez-Ruiz, B.
    BIOMOLECULAR ENGINEERING, 2006, 23 (04): : 135 - 147
  • [9] INSECTICIDE DETERMINATION WITH ENZYME ELECTRODES USING DIFFERENT ENZYME IMMOBILIZATION TECHNIQUES
    KUMARAN, S
    TRANMINH, C
    ELECTROANALYSIS, 1992, 4 (10) : 949 - 954
  • [10] Membrane electrodes for protein and enzyme electrochemistry
    Lojou, É