Pearls and Pitfalls of the Volar Locking Plating for Distal Radius Fractures

被引:9
作者
Im, Jin-Hyung [1 ]
Lee, Joo-Yup [1 ]
机构
[1] Catholic Univ Korea, Dept Orthoped Surg, Seoul, South Korea
关键词
Distal radius fractures; Volar locking plate; Implant selection;
D O I
10.1142/S242483551640004X
中图分类号
R61 [外科手术学];
学科分类号
摘要
Volar locking plate fixation has been widely accepted method for the treatment of unstable distal radius fractures. Although the results of volar locking plate fixation are encouraging, it may cause implant-related complications such as flexor or extensor tendon injuries. In depth understanding of anatomy of the distal radius is mandatory in order to obtain adequate fixation of the fracture fragments and to avoid these complications. This article will review the anatomic characteristics of the distal radius because selecting proper implant and positioning of the plate is closely related to the volar surface anatomy of the distal radius. The number and the length of distal locking screws are also important to provide adequate fixation strength to maintain fracture fixation. We will discuss the pros and cons of the variable-angle locking plate, which was introduced in an effort to provide surgeons with more freedom for fixation. Finally, we will discuss about correcting radial length and volar tilt by using eccentric drill holes and distal locking first technique.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 49 条
[1]  
Adham Mehdi N, 2009, Hand (N Y), V4, P406, DOI 10.1007/s11552-009-9180-0
[2]   Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures [J].
Al-Rashid, M. ;
Theivendran, K. ;
Craigen, M. A. C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (12) :1610-1612
[3]   Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[4]   Rupture of flexor pollicis longus tendon - A complication of volar plating of the distal radius [J].
Bell, JSP ;
Wollstein, R ;
Citron, ND .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :225-226
[5]   Comparative clinical study of locking screws versus smooth locking pegs in volar plating of distal radius fractures [J].
Boretto, J. G. ;
Pacher, N. ;
Giunta, D. ;
Gallucci, G. L. ;
Alfie, V. ;
De Carli, P. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2014, 39 (07) :755-760
[6]   Malunion of the distal radius [J].
Bushnell, Brandon D. ;
Bynum, Donald K. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2007, 15 (01) :27-40
[7]   FLEXOR POLLICIS LONGUS TENDON RUPTURES AFTER PALMAR PLATE FIXATION OF FRACTURES OF THE DISTAL RADIUS [J].
Casaletto, J. A. ;
Machin, D. ;
Leung, R. ;
Brown, D. J. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (04) :471-474
[8]   Management of distal radial fractures [J].
Chen, Neal C. ;
Jupiter, Jesse B. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (09) :2051-2062
[9]  
CHEN WS, 1990, CLIN ORTHOP RELAT R, P124
[10]   Trends in the United States in the Treatment of Distal Radial Fractures in the Elderly [J].
Chung, Kevin C. ;
Shauver, Melissa J. ;
Birkmeyer, John D. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) :1868-1873