FUNCTIONAL IMAGING OF CHANGES IN HUMAN INTRARENAL PERFUSION USING QUANTITATIVE DYNAMIC COMPUTED-TOMOGRAPHY

被引:31
作者
MILES, KA
HAYBALL, MP
DIXON, AK
机构
[1] ADDENBROOKES HOSP,DEPT RADIOL,CAMBRIDGE,ENGLAND
[2] ADDENBROOKES HOSP,DEPT MED PHYS,CAMBRIDGE,ENGLAND
[3] UNIV CAMBRIDGE,DEPT RADIOL,CAMBRIDGE,ENGLAND
关键词
COMPUTED TOMOGRAPHY; DYNAMIC; KIDNEY; PERFUSION; FUNCTIONAL IMAGING;
D O I
10.1097/00004424-199410000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Quantitative dynamic computed tomography was used with perfusion imaging to characterize intrarenal variations in perfusion in normal and abnormal human kidneys. METHODS. Perfusion images were obtained from 14 normal and four abnormal kidneys, comprising a renal tumor, an infarcted renal allograft, and two kidneys in a patient with cyclosporin toxicity. RESULTS. Images demonstrating quantifiable intrarenal variations in perfusion were consistently obtained. Normal cortical and medullary perfusion were 4.7 mL/min/mL and 1.1 mL/min/mL, respectively, consistent with accepted normal ranges. The changes in the abnormal kidneys corresponded with known pathophysiology. CONCLUSION. Computed tomography perfusion imaging creates quantifiable images of renal perfusion with a spatial resolution currently higher than any other functional imaging technique. It offers the opportunity to characterize renal diseases by their relative effects on cortical and medullary perfusion.
引用
收藏
页码:911 / 914
页数:4
相关论文
共 10 条
  • [1] VALIDATION OF USE OF XE-133 TO MEASURE INTRARENAL DISTRIBUTION OF BLOOD FLOW
    BLAUFOX, MD
    FROMOWITZ, A
    GRUSKIN, A
    MENG, CH
    ELKIN, M
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1970, 219 (02): : 440 - +
  • [2] GRUNEWALD SM, 1981, CLIN SCI, V61, P385
  • [3] JANSEN O, 1989, FORTSCHR RONTG NEUEN, V151, P473
  • [4] MEASUREMENT OF TISSUE PERFUSION BY DYNAMIC COMPUTED-TOMOGRAPHY
    MILES, KA
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (761) : 409 - 412
  • [5] FUNCTIONAL IMAGES OF HEPATIC PERFUSION OBTAINED WITH DYNAMIC CT
    MILES, KA
    HAYBALL, MP
    DIXON, AK
    [J]. RADIOLOGY, 1993, 188 (02) : 405 - 411
  • [6] COLOR PERFUSION IMAGING - A NEW APPLICATION OF COMPUTED-TOMOGRAPHY
    MILES, KA
    HAYBALL, M
    DIXON, AK
    [J]. LANCET, 1991, 337 (8742) : 643 - 645
  • [7] NONINVASIVE MEASUREMENT OF RENAL BLOOD-FLOW WITH TC-99M DTPA - COMPARISON WITH RADIOLABELED MICROSPHERES
    PETERS, AM
    BROWN, J
    HARTNELL, GG
    MYERS, MJ
    HASKELL, C
    LAVENDER, JP
    [J]. CARDIOVASCULAR RESEARCH, 1987, 21 (11) : 830 - 834
  • [8] NONINVASIVE MEASUREMENT OF BLOOD-FLOW AND EXTRACTION FRACTION
    PETERS, AM
    GUNASEKERA, RD
    HENDERSON, BL
    BROWN, J
    LAVENDER, JP
    DESOUZA, M
    ASH, JM
    GILDAY, DL
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 1987, 8 (10) : 823 - 837
  • [9] PIEPSZ A, 1989, EVALUATION RENAL FUN, P150
  • [10] MONOMER-DIMER CONTRAST-MEDIA IN RENAL CIRCULATION - EXPERIMENTAL ANGIOGRAPHY
    RUSSELL, SB
    BIOL, LI
    SHERWOOD, T
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1974, 47 (557) : 268 - 271