SERIAL ANGIOGRAPHIC FOLLOW-UP AFTER PALMAZ-SCHATZ STENT IMPLANTATION - COMPARISON WITH CONVENTIONAL BALLOON ANGIOPLASTY

被引:141
作者
KIMURA, T
NOSAKA, H
YOKOI, H
IWABUCHI, M
NOBUYOSHI, M
机构
[1] Department of Cardiology, Kokura Memorial Hospital, Kitakyushu
关键词
D O I
10.1016/0735-1097(93)90368-B
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. Serial angiographic follow-up study was designed to evaluate the temporal mode of lumen diameter changes after Palmaz-Schatz stent implantation, and the results were compared with those from a cohort of patients undergoing balloon angioplasty. Background. Restenosis remains a major limitation of balloon angioplasty. The Palmaz-Schatz balloon expandable coronary stent is now under clinical investigation to evaluate its efficacy in preventing restenosis. Methods. Serial angiographic follow-up study was performed the day after stent implantation and at 1, 3 and 6 months after the procedure. The stent group consisted of % patients who had 97 lesions with a single stent. A cohort of 179 patients with 192 lesions were selected as the balloon group by the criteria of final balloon size greater-than-or-equal-to 3 mm and lesion length <20 mm. Results. A significantly larger lumen diameter was obtained immediately after stent implantation (2.9 +/- 0.4 mm [mean +/- SD] in the stent group vs. 2.1 +/- 0.5 mm in the balloon group, p < 0.001). At 3 to 6 months of follow-up, a significantly larger lumen diameter was maintained in the stent group (2.2 +/- 0.6 vs. 1.5 +/- 0.7 mm, p < 0.001). The late restenosis rate according to a binary definition was significantly lower in the stent group (13% vs. 39%, p < 0.001). Stenosis exacerbation, frequently observed within 24 h after balloon angioplasty, was not found after stenting. Between the next day and 1 month, regression was dominant in the balloon group, whereas progression of stenosis was observed in the stent group. The greatest tendency to restenosis was observed in both groups between 1 and 3 months after the procedure. Between 3 and 6 months, significantly greater diameter loss was found in the stent group. Conclusions. The Palmaz-Schatz stent was effective in reducing the restenosis rate in this highly selected cohort of patients. Reduction in restenosis rate was dependent on a larger lumen obtained immediately. Late loss of diameter was significantly greater after stenting. The restenosis rate after stenting should be evaluated by follow-up angiography at 6 months rather than at 3 months, which is adequate after conventional balloon angioplasty.
引用
收藏
页码:1557 / 1563
页数:7
相关论文
共 22 条
[1]   INTIMAL PROLIFERATION OF SMOOTH-MUSCLE CELLS AS AN EXPLANATION FOR RECURRENT CORONARY-ARTERY STENOSIS AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
AUSTIN, GE ;
RATLIFF, NB ;
HOLLMAN, J ;
TABEI, S ;
PHILLIPS, DF .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (02) :369-375
[2]   RESTENOSIS AFTER CORONARY ANGIOPLASTY - THE PARADOX OF INCREASED LUMEN DIAMETER AND RESTENOSIS [J].
BEATT, KJ ;
SERRUYS, PW ;
LUIJTEN, HE ;
RENSING, BJ ;
SURYAPRANATA, H ;
DEFEYTER, P ;
VANDENBRAND, M ;
LAARMAN, GJ ;
ROELANDT, J ;
VANES, GA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) :258-266
[3]  
BONNER RF, 1991, CIRCULATION S2, V84, P197
[4]   ANGIOGRAPHIC AND CLINICAL OUTCOME OF INTRACORONARY STENTING - IMMEDIATE AND LONG-TERM RESULTS FROM A LARGE SINGLE-CENTER EXPERIENCE [J].
CARROZZA, JP ;
KUNTZ, RE ;
LEVINE, MJ ;
POMERANTZ, RM ;
FISHMAN, RF ;
MANSOUR, M ;
GIBSON, CM ;
SENERCHIA, CC ;
DIVER, DJ ;
SAFIAN, RD ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) :328-337
[5]   TRANSLUMINAL TREATMENT OF ARTERIOSCLEROTIC OBSTRUCTION - DESCRIPTION OF NEW TECHNIC + PRELIMINARY REPORT OF ITS APPLICATION [J].
DOTTER, CT ;
JUDKINS, MP .
CIRCULATION, 1964, 30 (05) :654-&
[6]   EFFECT OF INTRACORONARY STENTING ON INTIMAL DISSECTION AFTER BALLOON ANGIOPLASTY - RESULTS OF QUANTITATIVE AND QUALITATIVE CORONARY ANALYSIS [J].
FISCHMAN, DL ;
SAVAGE, MP ;
LEON, MB ;
SCHATZ, RA ;
ELLIS, SG ;
CLEMAN, MW ;
TEIRSTEIN, P ;
WALKER, CM ;
BAILEY, S ;
HIRSHFELD, JW ;
GOLDBERG, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (06) :1445-1451
[7]  
HAUDE M, 1991, BRIT HEART J, V66, P337
[8]   RESTENOSIS AFTER CORONARY ANGIOPLASTY - A MULTIVARIATE STATISTICAL-MODEL TO RELATE LESION AND PROCEDURE VARIABLES TO RESTENOSIS [J].
HIRSHFELD, JW ;
SCHWARTZ, JS ;
JUGO, R ;
MACDONALD, RG ;
GOLDBERG, S ;
SAVAGE, MP ;
BASS, TA ;
VETROVEC, G ;
COWLEY, M ;
TAUSSIG, AS ;
WHITWORTH, HB ;
MARGOLIS, JR ;
HILL, JA ;
PEPINE, CJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (03) :647-656
[9]   NOVEL-APPROACH TO THE ANALYSIS OF RESTENOSIS AFTER THE USE OF 3 NEW CORONARY DEVICES [J].
KUNTZ, RE ;
SAFIAN, RD ;
LEVINE, MJ ;
REIS, GJ ;
DIVER, DJ ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) :1493-1499
[10]   GENERALIZED-MODEL OF RESTENOSIS AFTER CONVENTIONAL BALLOON ANGIOPLASTY, STENTING AND DIRECTIONAL ATHERECTOMY [J].
KUNTZ, RE ;
GIBSON, CM ;
NOBUYOSHI, M ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) :15-25