ASYMMETRIC FAN TRANSMISSION CT ON SPECT SYSTEMS

被引:71
作者
CHANG, W
LONCARIC, S
HUANG, G
SANPITAK, P
机构
[1] Rush Presbyterian-St. Lukes Med. Center, Chicago, IL
关键词
D O I
10.1088/0031-9155/40/5/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For proper attenuation correction of SPECT images, a set of 3D attenuation maps specific to the imaging slices is needed. Among the many different approaches for deriving the attenuation maps, fan beam transmission CT (FBTCT), performed on the same SPECT system as emission imaging, has many promising and clinically practical features. The major problem of FBTCT is that the current SPECT systems do not have a large enough field of view (FOV) to cover the typical cross-sectional size of patients. To address this problem we have developed a novel asymmetric fan (AsF) sampling scheme to extend the FOV to practical sizes for clinical TCT imaging on existing SPECT systems. This AsF scheme samples only half of the intended FOV in each projection; the other half would be sampled in an opposing projection after detector rotation. We have implemented the AsF sampling on a three-head SPECT system through a specially designed source-collimator assembly. We have modified the conventional convolution backprojection algorithm to facilitate simple and fast image reconstruction. The feasibility of the approach is confirmed by the quality of the derived TCT images of various phantoms and human subjects. The AsF sampling scheme could also have applications in other general transmission CT systems.
引用
收藏
页码:913 / 928
页数:16
相关论文
共 28 条
  • [1] BAILEY DL, 1987, J NUCL MED, V28, P844
  • [2] PERFORMANCE-CHARACTERISTICS OF TRANSMISSION IMAGING USING A UNIFORM SHEET SOURCE WITH PARALLEL-HOLE COLLIMATION
    CAO, ZJ
    TSUI, BMW
    [J]. MEDICAL PHYSICS, 1992, 19 (05) : 1205 - 1212
  • [3] FICARO EP, 1994, J NUCL MED, V35, P652
  • [4] FREY EC, 1992, J NUCL MED, V33, P2238
  • [5] GALT JR, 1992, J NUCL MED, V33, P2232
  • [6] REVIEW OF CONVERGENT BEAM TOMOGRAPHY IN SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    GULLBERG, GT
    ZENG, GL
    DATZ, FL
    CHRISTIAN, PE
    TUNG, CH
    MORGAN, HT
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (03) : 507 - 534
  • [7] RECONSTRUCTION ALGORITHM FOR FAN BEAM WITH A DISPLACED CENTER-OF-ROTATION
    GULLBERG, GT
    CRAWFORD, CR
    TSUI, BMW
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) : 23 - 29
  • [8] A PROTON PROFILE MONITOR USING AN AMORPHOUS-SILICON PHOTODIODE-ARRAY
    HASEGAWA, K
    SUGIURA, H
    MOCHIKI, K
    TAKAHASHI, H
    HAYAKAWA, Y
    INADA, T
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 569 - 572
  • [9] HUANG SC, 1981, J NUCL MED, V22, P627
  • [10] Hubbell J. H., 1969, NAT STAND REF DATA S, P29