BIOMECHANICAL FACTORS ASSOCIATED WITH SHOE PEDAL INTERFACES - IMPLICATIONS FOR INJURY

被引:41
作者
GREGOR, RJ
WHEELER, JB
机构
[1] Department of Physiological Science, University of California at Los Angeles, Los Angeles, California
[2] Department of Health and Performance Sciences, The Georgia Institute of Technology, Atlanta, Georgia
关键词
D O I
10.2165/00007256-199417020-00004
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The principal demand on the body during cycling is on the lower extremities as they are responsible for producing a majority of the energy imparted to the bike. As a result the legs, due to high reactive forces between the foot and pedal, experience high loads on the joints. These loads may adversely affect joint tissues and contribute to overuse injuries, e.g. knee pain. The mechanical link between the leg and the bike is the shoe/pedal interface. This transmission site, by design, can either create smooth transfer of energy or abnormally high repetitive loads which are potentially injurious to the body. Incidence of lower extremity injury in cycling is high, and historically biomechanical analyses of this activity have focused their attention on either the rider or the bike, but not the link between the two. Recently, pedal designs have changed in response to complaints of sore knees with the development of pedals allowing varying degrees of float- This form of transmission is intended to enhance power transfer from rider to bike as well as minimise trauma to the legs by permitting the foot to rotate during the pedalling cycle in a toe-in/heel-out or heel-in/toe-out movement pattern. Recent evidence evidence suggests this type of pedal design does reduce trauma and maintains power output. This article reviews common lower extremity overuse injuries and biomechanical factors during the pedalling cycle with the primary focus on the shoe/pedal interface, We will summarise information available on lower extremity kinematics and kinetics as well as recent data specifically related to shoe/pedal inter-face kinetics, evaluation of different pedal types - specifically comparison between clipless 'fixed' and clipless 'float' systems - and discuss their resultant effect on lower extremity dynamics and their implications for injury.
引用
收藏
页码:117 / 131
页数:15
相关论文
共 49 条
[1]  
Amoroso A.T., Hennig E.M., Sanderson D.J., In-shoe pressure distribution for cycling at different cadences, Proceedings of the Second North American Congress on Biomechanics, pp. 249-250, (1992)
[2]  
Andrews J.G., The functional roles of the hamstrings and quadriceps during cycling: Lombard’s paradox revisited, Journal of Biomechanics, 20, pp. 565-575, (1987)
[3]  
Bohlmann J.T., Injuries in competitive cycling, Physician and Sports-medicine, 9, pp. 117-124, (1981)
[4]  
Broker J.P., Gregor R.J., A dual piezoelectric element force pedal for kinetic analysis of cycling, International Journal of Sport Biomechanics, 6, pp. 394-403, (1990)
[5]  
Broker J.P., Gregor R.J., Mechanical energy management in cycling: Source relations and mechanical energy expenditure, Medicine and Science in Sport and Exercise, 26, pp. 64-74, (1994)
[6]  
Broker J.P., Gregor R.J., Schmidt R.A., Extrinsic feedback and the learning of kinetic patterns in cycling, Journal of Applied Biomechanics, 9, pp. 111-113, (1993)
[7]  
Browning R.C., Lower extremity kinetics during cycling in elite tri-athletes in aerodynamic cycling, Masters Thesis, UCLA Department of Kinesiology, (1991)
[8]  
Cavanagh P.R., Sanderson D.J., The biomechanics of cycling: studies of the pedalling mechanics of elite pursuit riders, Science of Cycling, pp. 91-122, (1988)
[9]  
Coyle E.F., Feltner M.E., Kautz S.A., Hamilton M.T., Montain S.J., Et al., Physiological and biomechanical factors associated with elite endurance cycling performance, Medicine and Science in Sport and Exercise, 23, pp. 93-107, (1991)
[10]  
Desipres M., An electromyographic study of competitive road cycling conditions simulated on a treadmill, Biomechanics IV, pp. 349-355, (1974)