首页
学术期刊
论文检测
AIGC检测
热点
更多
数据
RADIOTHERAPY VERIFICATION FILM FOR ESTIMATING CUMULATIVE ENTRANCE SKIN EXPOSURE FOR FLUOROSCOPIC EXAMINATIONS
被引:19
作者
:
GEISE, RA
论文数:
0
引用数:
0
h-index:
0
机构:
VET ADM MED CTR, DEPT RADIOL, MINNEAPOLIS, MN 55417 USA
VET ADM MED CTR, DEPT RADIOL, MINNEAPOLIS, MN 55417 USA
GEISE, RA
[
1
]
ANSEL, HJ
论文数:
0
引用数:
0
h-index:
0
机构:
VET ADM MED CTR, DEPT RADIOL, MINNEAPOLIS, MN 55417 USA
VET ADM MED CTR, DEPT RADIOL, MINNEAPOLIS, MN 55417 USA
ANSEL, HJ
[
1
]
机构
:
[1]
VET ADM MED CTR, DEPT RADIOL, MINNEAPOLIS, MN 55417 USA
来源
:
HEALTH PHYSICS
|
1990年
/ 59卷
/ 03期
关键词
:
D O I
:
10.1097/00004032-199009000-00004
中图分类号
:
X [环境科学、安全科学];
学科分类号
:
08 ;
0830 ;
摘要
:
Measurement of skin entrance exposures during fluoroscopic procedures is complicated by the use of automatic exposure control devices and the presence of contrast media. Due to variability in positioning spot films from patient to patient, standard dosimeters, such as thermoluminescent, cannot be properly placed on the skin prior to examination. Prepackaged film of the type used for portal verification in radiation therapy held next to the patient’s skin in a specially modified patient examination govm was found to be useful for determining the entrance skin exposure from both fluoroscopy and spot films during air contrast barium enema exams. The usable sensitivity range of this film has been found satisfactory for exposure measurements at exposures and kVps typically used for gastrointestinal fluoroscopic procedures. Errors in exposure estimates due to changes in film speed and contrast with kVp are less than 5% for the range of kVps used. Errors from variations in beam quality due to the adjacency of scattering material are approximately 5%. Entrance exposures determined with film agreed with those determined from TLD measurements to within 21%, with an average difference of 9%. © 1990 Health Physics Society Pergamon Press plc.
引用
收藏
页码:295 / 298
页数:4
相关论文
共 8 条
[1]
A PHOTOGRAPHIC METHOD OF MEASURING FLUOROSCOPIC DOSE TO THE PATIENT
BLATZ, H
论文数:
0
引用数:
0
h-index:
0
BLATZ, H
EPP, ER
论文数:
0
引用数:
0
h-index:
0
EPP, ER
[J].
RADIOLOGY,
1961,
76
(01)
: 120
-
121
[2]
FILM DOSIMETRY SYSTEM FOR USE IN COMPUTED TOMOGRAPHY
DIXON, RL
论文数:
0
引用数:
0
h-index:
0
DIXON, RL
EKSTRAND, KE
论文数:
0
引用数:
0
h-index:
0
EKSTRAND, KE
[J].
RADIOLOGY,
1978,
127
(01)
: 255
-
258
[3]
A METHOD FOR ESTIMATING THE AVERAGE BONE-MARROW DOSE FROM SOME FLUOROSCOPIC EXAMINATIONS
LIUZZI, A
论文数:
0
引用数:
0
h-index:
0
LIUZZI, A
BLATZ, H
论文数:
0
引用数:
0
h-index:
0
BLATZ, H
EISENBUD, M
论文数:
0
引用数:
0
h-index:
0
EISENBUD, M
[J].
RADIOLOGY,
1964,
82
(01)
: 99
-
105
[4]
SULEIMAN OH, 1987, MED PHYS, V14, P454
[5]
SULEIMAN OH, 1988, RADIOLOGY, V169, P473
[6]
EXPOSURE PATTERN, SURFACE, BONE-MARROW INTEGRAL AND GONADAL DOSE FROM FLUOROSCOPY
TAKESHITA, K
论文数:
0
引用数:
0
h-index:
0
TAKESHITA, K
SAWADA, S
论文数:
0
引用数:
0
h-index:
0
SAWADA, S
ANTOKU, S
论文数:
0
引用数:
0
h-index:
0
ANTOKU, S
[J].
BRITISH JOURNAL OF RADIOLOGY,
1972,
45
(529)
: 53
-
+
[7]
ESTIMATION OF EXPOSURE PATTERN AND BONE MARROW AND GONADAL DOSES DURING FLUOROSCOPY
YOSHINAGA, H
论文数:
0
引用数:
0
h-index:
0
YOSHINAGA, H
TAKESHITA, K
论文数:
0
引用数:
0
h-index:
0
TAKESHITA, K
SAWADA, S
论文数:
0
引用数:
0
h-index:
0
SAWADA, S
RUSSELL, WJ
论文数:
0
引用数:
0
h-index:
0
RUSSELL, WJ
ANTOKU, S
论文数:
0
引用数:
0
h-index:
0
ANTOKU, S
[J].
BRITISH JOURNAL OF RADIOLOGY,
1967,
40
(473)
: 344
-
+
[8]
1987, ACCREDITATION MANUAL
←
1
→
共 8 条
[1]
A PHOTOGRAPHIC METHOD OF MEASURING FLUOROSCOPIC DOSE TO THE PATIENT
BLATZ, H
论文数:
0
引用数:
0
h-index:
0
BLATZ, H
EPP, ER
论文数:
0
引用数:
0
h-index:
0
EPP, ER
[J].
RADIOLOGY,
1961,
76
(01)
: 120
-
121
[2]
FILM DOSIMETRY SYSTEM FOR USE IN COMPUTED TOMOGRAPHY
DIXON, RL
论文数:
0
引用数:
0
h-index:
0
DIXON, RL
EKSTRAND, KE
论文数:
0
引用数:
0
h-index:
0
EKSTRAND, KE
[J].
RADIOLOGY,
1978,
127
(01)
: 255
-
258
[3]
A METHOD FOR ESTIMATING THE AVERAGE BONE-MARROW DOSE FROM SOME FLUOROSCOPIC EXAMINATIONS
LIUZZI, A
论文数:
0
引用数:
0
h-index:
0
LIUZZI, A
BLATZ, H
论文数:
0
引用数:
0
h-index:
0
BLATZ, H
EISENBUD, M
论文数:
0
引用数:
0
h-index:
0
EISENBUD, M
[J].
RADIOLOGY,
1964,
82
(01)
: 99
-
105
[4]
SULEIMAN OH, 1987, MED PHYS, V14, P454
[5]
SULEIMAN OH, 1988, RADIOLOGY, V169, P473
[6]
EXPOSURE PATTERN, SURFACE, BONE-MARROW INTEGRAL AND GONADAL DOSE FROM FLUOROSCOPY
TAKESHITA, K
论文数:
0
引用数:
0
h-index:
0
TAKESHITA, K
SAWADA, S
论文数:
0
引用数:
0
h-index:
0
SAWADA, S
ANTOKU, S
论文数:
0
引用数:
0
h-index:
0
ANTOKU, S
[J].
BRITISH JOURNAL OF RADIOLOGY,
1972,
45
(529)
: 53
-
+
[7]
ESTIMATION OF EXPOSURE PATTERN AND BONE MARROW AND GONADAL DOSES DURING FLUOROSCOPY
YOSHINAGA, H
论文数:
0
引用数:
0
h-index:
0
YOSHINAGA, H
TAKESHITA, K
论文数:
0
引用数:
0
h-index:
0
TAKESHITA, K
SAWADA, S
论文数:
0
引用数:
0
h-index:
0
SAWADA, S
RUSSELL, WJ
论文数:
0
引用数:
0
h-index:
0
RUSSELL, WJ
ANTOKU, S
论文数:
0
引用数:
0
h-index:
0
ANTOKU, S
[J].
BRITISH JOURNAL OF RADIOLOGY,
1967,
40
(473)
: 344
-
+
[8]
1987, ACCREDITATION MANUAL
←
1
→