RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF FINASTERIDE AND TAMSULOSIN IN TABLET FORMULATIONS

被引:0
作者
Mittal, Ashu [1 ]
Parmar, Shikha [2 ]
Imam, Syed Sarim [3 ]
Gilani, Sadaf J. [1 ]
Aqil, Mohd [3 ]
机构
[1] KIET Sch Pharm, Ghaziabad 201206, UP, India
[2] HRGI, Fac Pharm, Ghaziabad 201206, UP, India
[3] Jamia Hamdard, Fac Pharm, New Delhi 110062, India
来源
INDONESIAN JOURNAL OF PHARMACY | 2015年 / 26卷 / 01期
关键词
HPLC; tamsulosin; finasteride; validation; pharmaceutical dosage form;
D O I
10.14499/indonesianjpharm26iss1pp45
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The object of the present study was to develop a simple, precise simultaneous HPLC method for estimation of Tamsulosin (TAM) and Finasteride (FIN) in bulk and pharmaceutical dosage form. The method involves the use of easily available inexpensive laboratory solvents. The separation was achieved on spherisorb C-18 column with isocratic flow detected at 210nm. The mobile phase consisted of methanol: 0.03mM phosphate buffer pH 3.5 (70:30v/v) with flow rate of 1.0mL/min. A linear response was observed over concentration range of 4-40 mu g/mL for tamsulosin and 10-80 mu g/mL for finasteride. Limit of detection and limit of quantitation for tamsulosin were 1.13 mu g/mL and 3.43 mu g/mL, and for finasteride were 1.37 mu g/mL and 4.21 mu g/mL, respectively. The recovery of tamsulosin and finasteride was found to be in the range of 98.80-100.24% and 99.33-100.33%, respectively. The low % RSD value indicated a good precision and stability of the analytical method. The analysis concluded that the method was selective for simultaneous estimation of tamsulosin and finasteride can be potentially used for the estimation of these drugs in combined dosage form.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 17 条
[1]  
Amer Sawsan M., 2003, Farmaco (Lausanne), V58, P159, DOI 10.1016/S0014-827X(02)00015-0
[2]  
[Anonymous], 2006, MERCK IND ENC CHEM D, P1728
[3]  
[Anonymous], 2005, ICH INT C HARM TECHN
[4]  
Basavaiah K., 2007, E-J CHEM, V4, P109
[5]   Finasteride in biological fluids: Extraction and separation by a graphitized carbon black cartridge and quantification by high-performance liquid chromatography [J].
Carlucci, G ;
Mazzeo, P .
JOURNAL OF CHROMATOGRAPHY B, 1997, 693 (01) :245-248
[6]   Development and validation of an LC-MS assay for finasteride and its application to prostate cancer prevention trial sample analysis [J].
Chen, Xiaohong ;
Gardner, Erin R. ;
Price, Douglas K. ;
Figg, William D. .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (04) :356-361
[7]   PICOGRAM DETERMINATION OF FINASTERIDE IN HUMAN PLASMA AND SEMEN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ATMOSPHERIC-PRESSURE CHEMICAL-IONIZATION TANDEM MASS-SPECTROMETRY [J].
CONSTANZER, ML ;
CHAVEZ, CM ;
MATUSZEWSKI, BK .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 658 (02) :281-287
[8]   Quantitation of tamsulosin in human plasma by liquid chromatography-electrospray ionization mass spectrometry [J].
Ding, L ;
Li, LM ;
Tao, P ;
Yang, J ;
Zhang, ZX .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 767 (01) :75-81
[9]   A rapid, simple, specific liquid chromatographic-electrospray mass spectrometry method for the determination of finasteride in human plasma and its application to pharmacokinetic study [J].
Guo, Fanc-Qiu ;
Huang, Lan-Fang ;
Wong, Kin Ping ;
Dai, Yun-Hui ;
Li, Ya-Wen ;
Liang, Yi-Zeng ;
Huang, Ke-Long ;
Zhong, Ke-Jun ;
Wu, Ming-Han .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (04) :1507-1513
[10]   Determination of tamsulosin in human aqueous humor and serum by liquid chromatography-electrospray ionization tandem mass spectrometry [J].
Keski-Rahkonen, Pekka ;
Parssinen, Olavi ;
Leppanen, Esa ;
Mauriala, Timo ;
Lehtonen, Marko ;
Auriola, Seppo .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (02) :606-612