GLUCOSE-OXIDASE ELECTRODE BASED ON GRAPHITE AND METHYLTHIO TETRATHIAFULVALENE AS MEDIATOR

被引:5
|
作者
KULYS, J
BUCHRASMUSSEN, T
BECHGAARD, K
MARCINKEVICIENE, J
HANSEN, HE
机构
[1] NOVO NORDISK AS,DK-3400 HILLEROD,DENMARK
[2] UNIV COPENHAGEN,CISMI,DEPT CHEM,DK-2100 COPENHAGEN,DENMARK
关键词
GLUCOSE OXIDASE; GRAPHITE ELECTRODE; 4,5-DIMETHYL-4'-METHYLTHIO-DELTA 2,2'-BI-1,3-DITHIOLE (MTTTF);
D O I
10.1080/00032719308017971
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glucose sensor based on glucose oxidase and a new mediator - 4,5-dimethyl-4'-methylthio-DELTA 2,2'-bi-1,3-dithiole (MTTTF) is described. The background for sensor action is the effective MTTTF cation interaction (apparent bimolecular constant (2.0+/-0.5)*10(6) M-1 s-1 at 25-degrees-C and pH 7.0) with reduced glucose oxidase and the high electrochemical rate of mediator transformation. A glucose sensor was prepared by adsorbing mediator (MTTTF and glucose oxidase on graphite rods. The sensor responds to glucose at electrode potentials higher than 50 mV vs SCE, but the maximal activity is obtained at a potential of 250 mV. In air saturated solution the electrode shows a non-linear calibration curve with a half-saturation concentration 10.4 mM and Hill coefficient 2.08 at 250 mV. Sensor response changes little at pH 6.5-8.0. The energy of activation of the sensor response calculated from the Arrhenius equation was 64.5 kJ /mol and the temperature coefficient at 25-degrees-C was 9.2 %.
引用
收藏
页码:2535 / 2542
页数:8
相关论文
共 50 条
  • [11] AMPEROMETRIC ENZYME ELECTRODE FOR AEROBIC GLUCOSE MONITORING PREPARED BY GLUCOSE-OXIDASE IMMOBILIZED IN POLY(VINYLFERROCENIUM)
    GULCE, H
    OZYORUK, H
    CELEBI, SS
    YILDIZ, A
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 394 (1-2): : 63 - 70
  • [12] IMMOBILIZATION OF GLUCOSE-OXIDASE IN A POLY [VINYL ALCOHOL] MATRIX ON PLATINIZED GRAPHITE-ELECTRODES BY GAMMA-IRRADIATION
    GALIATSATOS, C
    IKARIYAMA, Y
    MARK, JE
    HEINEMAN, WR
    BIOSENSORS & BIOELECTRONICS, 1990, 5 (01) : 47 - 61
  • [13] Polyaniline-graphite composite film glucose oxidase electrode
    周海晖
    陈宏
    陈金华
    旷亚非
    Journal of Central South University, 2006, (06) : 653 - 657
  • [14] Polyaniline-graphite composite film glucose oxidase electrode
    Hai-hui Zhou
    Hong Chen
    Jin-hua Chen
    Ya-fei Kuang
    Journal of Central South University of Technology, 2006, 13 : 653 - 657
  • [15] GLUCOSE-SENSING CARBON PASTE ELECTRODE CONTAINING POLYETHYLENE GLYCOL-MODIFIED GLUCOSE-OXIDASE
    YABUKI, S
    MIZUTANI, F
    KATSURA, T
    BIOSENSORS & BIOELECTRONICS, 1992, 7 (10) : 695 - 700
  • [16] Polyaniline-graphite composite film glucose oxidase electrode
    Zhou Hai-hui
    Chen Hong
    Chen Jin-hua
    Kuang Ya-fei
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2006, 13 (06): : 653 - 657
  • [17] OPTIMIZATION OF A POLYPYRROLE GLUCOSE-OXIDASE BIOSENSOR
    FORTIER, G
    BRASSARD, E
    BELANGER, D
    BIOSENSORS & BIOELECTRONICS, 1990, 5 (06) : 473 - 490
  • [18] FUNCTIONAL LANGMUIR FILMS WITH GLUCOSE-OXIDASE
    ZAITSEV, SY
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1993, 75 : 211 - 216
  • [19] GLUCOSE BIOSENSOR USING GLUCOSE-OXIDASE IMMOBILIZED IN POLYANILINE
    PARENTE, AH
    MARQUES, ETA
    AZEVEDO, WM
    DINIZ, FB
    MELO, EHM
    FILHO, JLL
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1992, 37 (03) : 267 - 273
  • [20] THE CHARACTERIZATION OF LIPOSOMAL GLUCOSE-OXIDASE ELECTRODES FOR THE MEASUREMENT OF GLUCOSE
    TAYLOR, MA
    JONES, MN
    VADGAMA, PM
    HIGSON, SPJ
    BIOSENSORS & BIOELECTRONICS, 1995, 10 (3-4) : 251 - 260