Tissue-inspired phantoms: a new range of equivalent tissue simulating breast, cortical bone and lung tissue

被引:7
作者
Coulaud, J. [1 ]
Brumas, V. [1 ]
Fiallo, M. [1 ]
Sharrock, P. [2 ]
Gonneau, E. [1 ]
Courbon, F. [3 ]
Caselles, O. [3 ]
机构
[1] Univ Paul Sabatier, SIMAD, Toulouse, France
[2] Ecole Mines, RAPSODEE, Albi, France
[3] IUCT Oncopole, Inst Claudius Regaud, Toulouse, France
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2018年 / 4卷 / 03期
关键词
dosimetry; hydrogel; equivalent tissue; lung; bone; breast; MRI;
D O I
10.1088/2057-1976/aaac68
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new range of equivalent tissue materials has been formulated starting from proprietary gelatin-based gels. Depending on the formulation and the experimental conditions these materials have radiological properties close to breast tissue, compact bone or lung tissue with respect to photon, electron, and neutron interactions and they have also morphology and mechanical properties close to the biological specimen. These new equivalent-tissues materials contain paramagnetic elements and can be used for MRI dosimetry. This paper describes the preparation and the physical properties of these tissue-inspired formulations.
引用
收藏
页数:11
相关论文
共 34 条
  • [1] Andreo P, 2000, TECHNICAL REPORTS SE, V398
  • [2] Determination of paramagnetic gel sensitivity in low energy X-ray beam
    Ben Ahmed, Y.
    Coulaud, J.
    Ken, S.
    Parent, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S785 - S785
  • [3] Berger M. J., 1964, TABLES ENERGY LOSSES
  • [4] CASWELL RS, 1982, INT J APPL RADIAT IS, V33, P1227, DOI 10.1016/0020-708X(82)90246-0
  • [5] Polyvinyl alcohol-Fricke hydrogel and cryogel:: two new gel dosimetry systems with low Fe3+ diffusion
    Chu, KC
    Jordan, KJ
    Battista, JJ
    Van Dyk, J
    Rutt, BK
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04) : 955 - 969
  • [6] Characterization of paraffin based breast tissue equivalent phantom using a CdTe detector pulse height analysis
    Cubukcu, Solen
    Yucel, Haluk
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (04) : 877 - 884
  • [7] Incompatible mechanical properties in compact bone
    Currey, J
    [J]. JOURNAL OF THEORETICAL BIOLOGY, 2004, 231 (04) : 569 - 580
  • [8] A model of lung parenchyma stress relaxation using fractional viscoelasticity
    Dai, Zoujun
    Peng, Ying
    Mansy, Hansen A.
    Sandler, Richard H.
    Royston, Thomas J.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2015, 37 (08) : 752 - 758
  • [9] Davis P, 2003, J POLYM SCI A, V1, P799, DOI DOI 10.1002/POL.1963.100010217
  • [10] FlexyDos3D: a deformable anthropomorphic 3D radiation dosimeter: radiation properties
    De Deene, Y.
    Skyt, P. S.
    Hil, R.
    Booth, J. T.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (04) : 1543 - 1563