OPTIMIZED PULSE SEQUENCES FOR MAGNETIC-RESONANCE MEASUREMENT OF AORTIC CROSS-SECTIONAL AREAS

被引:8
作者
BUONOCORE, MH
BOGREN, H
机构
[1] Division of Diagnostic Radiology, UC Davis Medical Center, Sacramento
关键词
MAGNETIC RESONANCE (MR); PULSE SEQUENCES; EXPERIMENTAL; AORTA; MR STUDIES;
D O I
10.1016/0730-725X(91)90433-M
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was done to improve the ability of magnetic resonance (MR) imaging to provide clear cross-sectional images of the ascending and descending aorta in diastole. The study was motivated by interest in measuring the regional compliance of the ascending aorta, which requires determination of the change in cross sectional area of the vessel between systole and diastole. In diastolic images, residual signal from slow flowing blood and flow artifact consistently obscured the inner boundary of the aortic wall and precluded tracing and measurement of the cross sectional area. We concluded that cross sectional area measurement of the ascending aorta was impossible on our system using standard spin echo sequences. To improve wall delineation in diastolic images, SAT pulses were optimized with respect to pulse timing, slice thickness, and gap. Optimized SAT pulses greatly improved the delineation of the vessel wall by removing unwanted signal from flowing spins. Measurement precision was vastly improved by running two scans with and without flow compensation, and correlating visually and numerically the area measurements from each. We established that each image should be measured by two independent observers and traced three times by each. Using these procedures, diastolic cross-sectional areas of the mid-ascending aorta could be measured with a precision of 2.5%, and the change of cross-sectional area between systole and diastole could be measured with a precision of 10.8%. These measurements were precise enough to detect CAD patients with low aortic compliance from the age-matched controls previously reported in one study. The test based on cross sectional area measurement, with a false positive detection rate of 5%, had a false negative rate of 58%. Compliance measurements by MR at 1.5 T could become clinically useful if normal and abnormal populations are sufficiently separated.
引用
收藏
页码:435 / 447
页数:13
相关论文
共 43 条
  • [21] Aortic Root Dilatation in Adults with Surgically Repaired Tetralogy of Fallot A Multicenter Cross-Sectional Study
    Mongeon, Francois-Pierre
    Gurvitz, Michelle Z.
    Broberg, Craig S.
    Aboulhosn, Jamil
    Opotowsky, Alexander R.
    Kay, Joseph D.
    Valente, Anne Marie
    Earing, Michael G.
    Lui, George K.
    Fernandes, Susan M.
    Gersony, Deborah R.
    Cook, Stephen C.
    Ting, Jennifer Grando
    Nickolaus, Michelle J.
    Landzberg, Michael J.
    Khairy, Paul
    CIRCULATION, 2013, 127 (02) : 172 - +
  • [22] EFFECTS OF SUPERPARAMAGNETIC IRON-OXIDE (AMI-25) ON LIVER AND SPLEEN IMAGING USING SPIN-ECHO AND FAST SPIN-ECHO MAGNETIC-RESONANCE PULSE SEQUENCES
    SCHWARTZ, LH
    SELTZER, SE
    ADAMS, DF
    TEMPANY, CMC
    PIWNICAWORMS, DR
    SILVERMAN, SG
    HERMAN, L
    HERMAN, LT
    HOOSHMAND, R
    INVESTIGATIVE RADIOLOGY, 1994, 29 : S21 - S23
  • [23] Sport PRactice and its Effects on aortic size and valve function in bicuspid Aortic valve Disease: a cross-sectional report from the SPREAD study
    D'Ascenzi, Flavio
    Cavigli, Luna
    Cameli, Matteo
    Claessen, Guido
    van Craenenbroeck, Emeline M.
    Cavarretta, Elena
    D'Andrea, Antonello
    Sanz De la Garza, Maria
    Eijsvogels, Thijs M. H.
    van Kimmenade, Roland R. J.
    Galian-Gay, Laura
    Halle, Martin
    Mandoli, Giulia Elena
    Mantegazza, Valentina
    Moreo, Antonella
    Schreurs, Bibi
    Stefani, Laura
    Zamorano, Jose L.
    Pelliccia, Antonio
    Papadakis, Michael
    BRITISH JOURNAL OF SPORTS MEDICINE, 2024, 58 (23) : 1419 - 1425
  • [24] HELICAL AND RETROGRADE SECONDARY FLOW PATTERNS IN THE AORTIC-ARCH STUDIED BY 3-DIRECTIONAL MAGNETIC-RESONANCE VELOCITY MAPPING
    KILNER, PJ
    YANG, GZ
    MOHIADDIN, RH
    FIRMIN, DN
    LONGMORE, DB
    CIRCULATION, 1993, 88 (05) : 2235 - 2247
  • [25] Non-Invasive Assessment of Arterial Stiffness: Pulse Wave Velocity, Pulse Wave Analysis and Carotid Cross-Sectional Distensibility: Comparison between Methods
    Salvi, Paolo
    Valbusa, Filippo
    Kearney-Schwartz, Anna
    Labat, Carlos
    Grillo, Andrea
    Parati, Gianfranco
    Benetos, Athanase
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (08)
  • [26] The Assessment of Aortic Pulse Wave Velocity Using 4D Flow Magnetic Resonance Imaging: Methods Comparison
    Houriez-Gombaud-Saintonge, Sophia
    Mousseaux, Elie
    Bargiotas, Ioannis
    De Cesare, Alain
    Dietenbeck, Thomas
    Bouaou, Kevin
    Redheuil, Alban
    Soulat, Gilles
    Gencer, Umit
    Craiem, Damian
    Chenoune, Yasmina
    Kachenoura, Nadjia
    2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [27] Magnetic resonance imaging of the kidney: Evaluation of new pulse sequences and comparison of CT in differential diagnosis of space-occupying lesions
    Kreft, B
    Steudel, A
    Textor, J
    Novak, D
    Muller, B
    Miersch, WDE
    Schild, H
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1996, 164 (03): : 212 - 217
  • [28] Pulse sequences as tissue property filters (TP-filters): a way of understanding the signal, contrast and weighting of magnetic resonance images
    Young, Tan R.
    Szeverenyi, Nikolaus M.
    Du, Jiang
    Bydder, Graeme M.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (05) : 1080 - 1120
  • [29] Use of Synchrotron Radiation to Accurately Assess Cross-Sectional Area Reduction of the Aortic Branch Ostia Caused by Suprarenal Stent Wires
    Sun, Zhonghua
    Ng, Curtise K. C.
    JOURNAL OF ENDOVASCULAR THERAPY, 2017, 24 (06) : 870 - 879
  • [30] Detection of hepatic VX2 carcinomas with ferucarbotran-enhanced magnetic resonance imaging in rabbits: Comparison of nine pulse sequences
    Kim, Seong Hyun
    Choi, Dongil
    Lim, Hyo K.
    Kim, Min Ju
    Jang, Kyung Mi
    Kim, Seung Hoon
    Lee, Won Jae
    Lee, Jongmee
    Jeon, Yong Hwan
    Lim, Jae Hoon
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 59 (03) : 413 - 423