SURGICAL-MANAGEMENT OF CORNEAL PERFORATION WITH EXPANDED POLYTETRAFLUOROETHYLENE (GORE-TEX)

被引:0
|
作者
LEGEAIS, JM
RENARD, G
DHERMIES, F
ROSSI, C
POULIQUEN, Y
机构
来源
OPHTHALMIC SURGERY AND LASERS | 1991年 / 22卷 / 04期
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We report a series of six patients with spontaneous corneal perforations successfully treated with a temporary graft of expanded polytetrafluoroethylene (Gore-Tex(TM) until a definitive penetrating keratoplasty could be performed. Two other patients had a paralimbic perforation treated with an artificial lamelar Gore-Tex graft. No infection or extrusion developed, and the artificial graft kept the anterior chamber tight in all cases. Gore-Tex appears to be a safe and effective material for use in treating acute central and peripheral corneal perforation.
引用
收藏
页码:213 / 217
页数:5
相关论文
共 50 条
  • [1] The Use of Expanded Polytetrafluoroethylene (Gore-Tex) in Rhinoplasty
    Ronald Gruber
    Aesthetic Plastic Surgery, 2007, 31 : 349 - 349
  • [2] The Use of Expanded Polytetrafluoroethylene (Gore-Tex) in Rhinoplasty
    Selcuk Inanli
    Murat Sari
    Serdar Baylancicek
    Aesthetic Plastic Surgery, 2007, 31 : 345 - 348
  • [3] The use of expanded polytetrafluoroethylene (Gore-Tex) in rhinoplasty
    Gruber, Ronald
    AESTHETIC PLASTIC SURGERY, 2007, 31 (04) : 349 - 349
  • [4] REINFORCED EXPANDED POLYTETRAFLUOROETHYLENE (GORE-TEX) GRAFTS FOR HEMODIALYSIS
    KESTER, RC
    BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1978, 6 (04): : 331 - 340
  • [5] SMALL VESSEL REPLACEMENT WITH GORE-TEX (EXPANDED POLYTETRAFLUOROETHYLENE)
    FLORIAN, A
    COHN, LH
    DAMMIN, GJ
    COLLINS, JJ
    ARCHIVES OF SURGERY, 1976, 111 (03) : 267 - 270
  • [6] BEHAVIOR OF INFECTED EXPANDED POLYTETRAFLUOROETHYLENE (GORE-TEX) ARTERIAL PROSTHESES
    WEISS, JP
    LORENZO, FV
    CAMPBELL, CD
    MYEROWITZ, RL
    WEBSTER, MW
    CLINICAL RESEARCH, 1978, 26 (04): : A642 - A642
  • [7] Expanded polytetrafluoroethylene (Gore-Tex) augmentation of deep nasolabial creases
    Robertson, KM
    Dyer, WK
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1999, 125 (04) : 456 - 461
  • [8] BEHAVIOR OF INFECTED ARTERIAL PROSTHESES OF EXPANDED POLYTETRAFLUOROETHYLENE (GORE-TEX)
    WEISS, JP
    LORENZO, FV
    CAMPBELL, CD
    MYEROWITZ, RL
    WEBSTER, MW
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1977, 73 (04): : 630 - 636
  • [9] Evaluation of Tissue Response to Gore-Tex (Expanded Polytetrafluoroethylene) Implantation
    Serin, Gediz
    Baylancicek, Serdar
    Aksoy, Elif
    Polat, Senol
    Saglican, Yesim
    Inanli, Selcuk
    JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (04) : 1428 - 1430
  • [10] Histological study of expanded polytetrafluoroethylene (Gore-Tex®) implanted in the human nose
    Park, Chan Hum
    RHINOLOGY, 2008, 46 (04) : 317 - 323