A comparative analysis of angular cephalometric values between CBCT generated lateral cephalograms versus digitized conventional lateral cephalograms

被引:11
作者
Chung, Raymond-R. [1 ]
Lagravere, Manuel-O. [2 ]
Flores-Mir, Carlos [2 ]
Heo, Giseon [3 ]
Carey, Jason P. [4 ]
Major, Paul-W. [2 ]
机构
[1] Prat Privee, Edmonton, AB, Canada
[2] Univ Alberta, Fac Med & Dent, Programme Orthodontie, Edmonton, AB, Canada
[3] Univ Alberta, Fac Med & Dent, Dept Dent, Biostatist, Edmonton, AB, Canada
[4] Univ Alberta, Fac Genie, Genie Mecan, Edmonton, AB, Canada
关键词
Cone-Beam Computed Tomography; Cephalometry; Reliability; Orthodontics;
D O I
10.1016/S1761-7227(09)73505-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study compared angular cephalometric values from scanned traditional lateral cephalograms versus CBCT generated slices. Traditional lateral cephalograms (using Orthoceph OC100) and volumetric CBCT imaging (using NewTom 3G Volume Scanner) were taken from 36 patients. Lateral cephalometric analysis using Dolphin 3D was performed on the respective imported radiographic data and ten angular measurements were evaluated. The reliability of measurements was evaluated with an intra-class correlation coefficient (ICC). Paired MANOVA was used to compare differences in measurements between the two image modalities. Inter-rater reliability demonstrated high reliability in 90% of the measurements (ICC >0.8). A high intra-rater reproducibility (ICC >0.8) was demonstrated in all angles. No significant difference in the angular measurements was detected between the two image modalities (paired MANOVA p >0.1, alpha =0.05). A lateral slice from CBCT imaging can be used to perform traditional cephalometric analysis with levels of precision and accuracy comparable to traditional lateral cephalometrics.
引用
收藏
页码:308 / 321
页数:14
相关论文
共 38 条
[1]   PORION AND CONDYLE AS CEPHALOMETRIC LANDMARKS - AN ERROR STUDY [J].
ADENWALLA, ST ;
KRONMAN, JH ;
ATTARZADEH, F .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1988, 94 (05) :411-415
[2]   THE EFFECT OF PROJECTION ERRORS ON CEPHALOMETRIC LENGTH MEASUREMENTS [J].
AHLQVIST, J ;
ELIASSON, S ;
WELANDER, U .
EUROPEAN JOURNAL OF ORTHODONTICS, 1986, 8 (03) :141-148
[3]  
Ahlqvist J, 1983, Dentomaxillofac Radiol, V12, P101
[4]  
AHLQVIST J, 1988, EUR J ORTHODONT, V10, P353
[5]   RELIABILITY OF HEAD FILM MEASUREMENTS .2. CONVENTIONAL ANGULAR AND LINEAR MEASURES [J].
BAUMRIND, S ;
FRANTZ, RC .
AMERICAN JOURNAL OF ORTHODONTICS, 1971, 60 (05) :505-&
[6]  
Baumrind Sheldon, 2006, J Calif Dent Assoc, V34, P831
[7]   Current concepts in maxillofacial imaging [J].
Boeddinghaus, Rudolf ;
Whyte, Andy .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 66 (03) :396-418
[8]  
BRODIE A. G., 1949, JOUR ORAL SURG, V7, P185
[9]   A comparison of scanned lateral cephalograms with corresponding original radiographs [J].
Bruntz, Lance Q. ;
Palomo, J. Martin ;
Baden, Sally ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2006, 130 (03) :340-348
[10]   Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications [J].
Cavalcanti, MGP ;
Rocha, SS ;
Vannier, MW .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (03) :170-176