Evaluation of combining bony anatomy and soft tissue position correction strategies for IMRT prostate cancer patients

被引:18
作者
Adamczyk, Marta [1 ]
Piotrowski, Tomasz [1 ]
Adamiak, Ewa [2 ]
机构
[1] Greater Poland Canc Ctr, Dept Med Phys, 15th Garbary St, PL-61866 Poznan, Poland
[2] Greater Poland Canc Ctr, Radiotherapy Ward 1, PL-61866 Poznan, Poland
关键词
Prostate cancer; Radiotherapy; IMRT;
D O I
10.1016/j.rpor.2012.01.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Radiotherapy treatment requires delivering high homogenous dose to target volume while sparing organs at risk. That is why accurate patient positioning is one of the most important steps during the treatment process. It reduces set-up errors which have a strong influence on the doses given to the target and surrounding tissues. Aim: The aim of this study was to investigate the efficiency of combining bony anatomy and soft tissue imaging position correction strategies for patients with prostate cancer. Materials and methods: The study based on pre-treatment position verification results determined for 10 patients using kV images and CBCT match. At the same patients' position, two orthogonal kV images and set of CT scans were acquired. Both verification methods gave the information about patients' position changes in vertical, longitudinal and lateral directions. Results: For 93 verifications, the mean values of kV shifts in vertical, longitudinal and lateral directions equaled: -0.11 +/- 0.54 cm, 0.26 +/- 0.38 cm and -0.06 +/- 0.47 cm, respectively. The same values achieved for CBCT matching equaled: 0.07 +/- 0.62 cm, 0.22 +/- 0.36 cm and -0.02 +/- 0.45 cm. Statistically significant changes between the values of shifts received during the first week of treatment and the rest time of the irradiation process were found for 2 patients in the lateral direction and 2 patients in vertical direction among kV results and for 3 patients in the longitudinal direction among CBCT results. A significant difference between kV and CBCT match results was found in the vertical direction. Conclusions: In clinical practice, CBCT combined with kV or even portal imaging improves precision and effectiveness of prostate cancer treatment accuracy. (c) 2012 Greater Poland Cancer Centre, Poland. Published by Elsevier Urban & Partner Sp. z.o.o. All rights reserved.
引用
收藏
页码:104 / 109
页数:6
相关论文
共 30 条
  • [1] A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES
    BEL, A
    VANHERK, M
    BARTELINK, H
    LEBESQUE, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 253 - 260
  • [2] Fiducial-based quantification of prostate tilt using cone beam computer tomography (CBCT)
    Boda-Heggemann, Judit
    Koehler, Frederick
    Wertz, Hansjoerg
    Wetzel, Grit
    Riesenacker, Nadja
    Schaefer, Joerg
    Lohr, Frank
    Wenz, Frederik
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 85 (02) : 247 - 250
  • [3] A semi-automated 2D/3D marker-based registration algorithm modelling prostate shrinkage during radiotherapy for prostate cancer
    Budiharto, Tom
    Slagmolen, Pieter
    Hermans, Jeroen
    Maes, Frederik
    Verstraete, Jan
    Van den Heuvel, Frank
    Depuydt, Tom
    Oyen, Raymond
    Haustermans, Karin
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 90 (03) : 331 - 336
  • [4] Dosimetric and physical comparison of IMRT and CyberKnife plans in the treatment of localized prostate cancer
    Ceylan, Cemile
    Kucuk, Nadir
    Ayata, Hande Bas
    Guden, Metin
    Engin, Kayihan
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2010, 15 (06) : 181 - 189
  • [5] A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload
    De Boer, HCJ
    Heijmen, BJM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (05): : 1350 - 1365
  • [6] Comparison of transabdominal ultrasound and electromagnetic transponders for prostate localization: Clinical experience in a large patient population
    Foster, R. D.
    Chetty, I. J.
    Li, H.
    Enke, C. A.
    Willoughby, T. R.
    Kupelian, P.
    Solberg, T. D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S650 - S650
  • [7] Grzadziel A, 2007, REP PRACT ONCOL RADI, V12, P307
  • [8] Assuring high quality treatment delivery in clinical trials - Results from the Trans-Tasman Radiation Oncology Group (TROG) study 03.04 "RADAR" set-up accuracy study
    Haworth, Annette
    Kearvell, Rachel
    Greer, Peter B.
    Hooton, Ben
    Denham, James W.
    Lamb, David
    Duchesne, Gillian
    Murray, Judy
    Joseph, David
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 90 (03) : 299 - 306
  • [9] Set-up verification using portal imaging; review of current clinical practice
    Hurkmans, CW
    Remeijer, P
    Lebesque, JV
    Mijnheer, BJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 2001, 58 (02) : 105 - 120
  • [10] A qualitative and a quantitative analysis of an auto-segmentation module for prostate cancer
    Huyskens, Dominique P.
    Maingon, Philippe
    Vanuytsel, Luc
    Remouchamps, Vincent
    Roques, Tom
    Dubray, Bernard
    Haas, Benjamin
    Kunz, Patrik
    Coradi, Thomas
    Buehlman, Rene
    Reddick, Robin
    Van Esch, Ann
    Salamon, Emile
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 90 (03) : 337 - 345