REMOVAL OF DISSOLVED-OXYGEN FROM WATER - A COMPARISON OF 4 COMMON TECHNIQUES

被引:263
作者
BUTLER, IB [1 ]
SCHOONEN, MAA [1 ]
RICKARD, DT [1 ]
机构
[1] SUNY STONY BROOK,DEPT EARTH & SPACE SCI,STONY BROOK,NY 11794
关键词
D O I
10.1016/0039-9140(94)80110-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four common techniques for the removal of dissolved oxygen from water have been examined: boiling at 1 atm, boiling under reduced pressure, purging with N2 and sonication under reduced pressure. After treatment, the residual oxygen in solution was analysed by the Winkler method. Nitrogen purging for 20-40 min at flow rate of 25 mL/s was found to be the most effective oxygen removal method. Boiling at 1 atm was found to be the least effective. None of the techniques evaluated here lead to complete removal of oxygen. The concentration of residual dissolved oxygen after purging for 20-40 minutes with nitrogen is 0.2-0.4 ppm.
引用
收藏
页码:211 / 215
页数:5
相关论文
共 16 条
[1]  
ARAKAKI T, 1991, GEOCHIM COSMOCHIM AC, V57, P9
[2]  
BUTLER IB, UNPUB INORGANIC SELF
[3]  
Clesceri LS., 1989, STANDARD METHODS EXA, V17
[4]  
Drever J.I, GEOCHEMISTRY NATURAL, V3rd
[5]   AN ELECTROKINETIC STUDY OF PYRITE OXIDATION [J].
FORNASIERO, D ;
EIJT, V ;
RALSTON, J .
COLLOIDS AND SURFACES, 1992, 62 (1-2) :63-73
[6]  
Hitchman M., 1978, MEASUREMENT DISSOLVE
[7]  
Hungate R.E., 1969, METHODS MICROBIOLOGY
[8]   POTENTIAL-PH EQUILIBRIUM DIAGRAMS FOR THE SYSTEM S-H2O FROM 25-DEGREES-C TO 150-DEGREES-C - INFLUENCE OF ACCESS OF OXYGEN IN SULFIDE SOLUTIONS [J].
POURBAIX, M ;
POURBAIX, A .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1992, 56 (08) :3157-3178
[9]  
REED MH, 1990, SOLTHERM DATA BASE E