VERIFICATION OF ENDOTRACHEAL-TUBE PLACEMENT WITH COLORIMETRIC END-TIDAL CO2 DETECTION

被引:106
|
作者
MACLEOD, BA [1 ]
HELLER, MB [1 ]
GERARD, J [1 ]
YEALY, DM [1 ]
MENEGAZZI, JJ [1 ]
机构
[1] UNIV PITTSBURGH,AFFILIATED RESIDENCY EMERGENCY MED,PITTSBURGH,PA 15213
关键词
carbon dioxide; intubation; endotracheal intubation;
D O I
10.1016/S0196-0644(05)80937-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: To determine the ability of a disposable colorimetric CO2 detector to accurately confirm or refute endotracheal tube placement. Design: Two hundred fifty prospective emergency intubations. Setting: Emergency intubations performed in the emergency department, helicopter, and prehospital ground environment. Type of participants: Intubations were performed by emergency medicine residents, paramedics, and flight nurses. Interventions: The FEF(TM) CO2 detector was applied after 250 emergency intubations. Notation of color change indicating intratracheal placement was recorded in each case. Confirmation or refutation of the detector's results was determined subsequently through traditional methods. Results: The sensitivity for confirmation of endotracheal intubation in the 137 patients with a palpable pulse was 100%. However, only 76 of 103 patients (sensitivity, 72%) in cardiac arrest had endotracheal intubation confirmed by color change. The device was uniformly specific for tracheal intubation in 73 arrested patients in whom a color change was noted (100%). There was one instance (of a total of seven misintubations) in which a positive color change was noted, but the tube was not intratracheal (specificity, 86%). Overall sensitivity for tracheal intubation was 88% (95% confidence limits; range, 0.83 to 0.92), and specificity for tracheal intubation was 92% (95% confidence limits; range, 0.62 to 0.99). Conclusion: The FEF(TM) colorimetric detector reliably detects intracheal placement in the nonarrested patient. Its use in prolonged cardiac arrest merits further study.
引用
收藏
页码:267 / 270
页数:4
相关论文
共 50 条
  • [1] COLORIMETRIC END-TIDAL CO2 DETECTOR FOR VERIFICATION OF ENDOTRACHEAL-TUBE PLACEMENT IN OUT-OF-HOSPITAL CARDIAC-ARREST
    HAYDEN, SR
    SCIAMMARELLA, J
    VICCELLIO, P
    THODE, H
    DELAGI, R
    ACADEMIC EMERGENCY MEDICINE, 1995, 2 (06) : 499 - 502
  • [2] VALIDITY OF A DISPOSABLE END-TIDAL CO2 DETECTOR IN VERIFYING ENDOTRACHEAL-TUBE PLACEMENT IN INFANTS AND CHILDREN
    BHENDE, MS
    THOMPSON, AE
    COOK, DR
    SAVILLE, AL
    ANNALS OF EMERGENCY MEDICINE, 1992, 21 (02) : 142 - 145
  • [3] CONTINUOUS END-TIDAL CO2 SAMPLING WITHIN THE PROXIMAL ENDOTRACHEAL-TUBE ESTIMATES ARTERIAL CO2 TENSION IN INFANTS
    RICH, GF
    SCONZO, JM
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1991, 38 (02): : 201 - 203
  • [4] CONFIRMATION OF ENDOTRACHEAL-TUBE PLACEMENT - A MINIATURIZED INFRARED QUALITATIVE CO2 DETECTOR
    VUKMIR, RB
    HELLER, MB
    STEIN, KL
    ANNALS OF EMERGENCY MEDICINE, 1991, 20 (07) : 726 - 729
  • [5] VALIDITY OF A DISPOSABLE END-TIDAL CARBON-DIOXIDE DETECTOR IN VERIFYING ENDOTRACHEAL-TUBE POSITION IN PIGLETS
    BHENDE, MS
    THOMPSON, AE
    HOWLAND, DF
    CRITICAL CARE MEDICINE, 1991, 19 (04) : 566 - 568
  • [6] A DISPOSABLE END-TIDAL CO2 DETECTOR TO VERIFY ENDOTRACHEAL INTUBATION
    ANTON, WR
    GORDON, RW
    JORDAN, TM
    POSNER, KL
    CHENEY, FW
    ANNALS OF EMERGENCY MEDICINE, 1991, 20 (03) : 271 - 275
  • [7] An Update on End-Tidal CO2 Monitoring
    Selby, Samuel T.
    Abramo, Thomas
    Hobart-Porter, Nicholas
    PEDIATRIC EMERGENCY CARE, 2018, 34 (12) : 888 - 892
  • [8] Use of Maximum End-Tidal CO2 Values to Improve End-Tidal CO2 Monitoring Accuracy
    Galia, Fabrice
    Brimioulle, Serge
    Bonnier, Frederic
    Vandenbergen, Nicolas
    Dojat, Michel
    Vincent, Jean-Louis
    Brochard, Laurent J.
    RESPIRATORY CARE, 2011, 56 (03) : 278 - 283
  • [9] Misleading end-tidal CO2 tensions
    Wahba, RWM
    Tessler, MJ
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1996, 43 (08): : 862 - 866
  • [10] CLINICAL UTILITY OF A COLORIMETRIC END-TIDAL CO2 DETECTOR IN CARDIOPULMONARY-RESUSCITATION AND EMERGENCY INTUBATION
    VARON, AJ
    MORRINA, J
    CIVETTA, JM
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (04): : 289 - 293