STUDY OF THE QUALITY OF DUPLICATED RADIOGRAPHS

被引:11
作者
ERALES, FA [1 ]
MANSONHING, LR [1 ]
机构
[1] UNIV ALABAMA,DEPT DENT RADIOL,BIRMINGHAM,AL 35294
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS | 1979年 / 47卷 / 01期
关键词
D O I
10.1016/0030-4220(79)90110-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The resolution, contrast, and clinical appearance of radiographs and duplicate radiographs made with two types of duplicating film were compared. Duplicating conditions evaluated were type and shape of light, light-film distance, type of exposure surface, and developer temperature. Major observations were as follows; both Kodak and DuPont films produced clinically acceptable duplicates; Kodak film was faster; DuPont film responded better in incandescent photoflood light than Kodak film; clear glass with appropriate light-film distance was the best exposure surface. © 1979.