WEAR INDUCED BY MOTION BETWEEN BONE AND TITANIUM OR COBALT-CHROME ALLOYS

被引:46
作者
BISCHOFF, UW
FREEMAN, MAR
SMITH, D
TUKE, MA
GREGSON, PJ
机构
[1] ROYAL LONDON HOSP,COLL MED,BONE & JOINT RES UNIT,LONDON E1 1AD,ENGLAND
[2] FINSBURY INSTRUMENTS LTD,LEATHERHEAD KT22 0BA,SURREY,ENGLAND
[3] UNIV SOUTHAMPTON,SOUTHAMPTON SO9 5NH,HANTS,ENGLAND
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1994年 / 76B卷 / 05期
关键词
D O I
10.1302/0301-620X.76B5.8083256
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied the wear generated by motion between polished and shot-blasted titanium-alloy (Ti-6Al-4V) or cobalt-chrome alloy (Co-Cr) surfaces and cortical bone in vitro. Semicircular sections of human proximal femoral cortex were reamed to fit metal cylinders of each alloy. The cylinders were then fitted in the bone, loaded and rotated in physiological saline. Ti-alloy resulted in more wear both of the bone and of the metal than did Co-Cr alloy. Metal wear was reduced and bone wear was increased by shot-blasting, a procedure which introduces surface residual stresses and roughens the metal surface. We conclude that when there is gross motion between a metal implant and bone, Ti-alloy is likely to generate more wear debris than Co-Cr alloy. The least wear both of bone and of metal was produced by polished Co-Cr.
引用
收藏
页码:713 / 716
页数:4
相关论文
共 22 条
[1]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]   METALLOSIS ASSOCIATED WITH A STABLE TITANIUM-ALLOY FEMORAL COMPONENT IN TOTAL HIP-REPLACEMENT - A CASE-REPORT [J].
BLACK, J ;
SHERK, H ;
BONINI, J ;
ROSTOKER, WR ;
SCHAJOWICZ, F ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (01) :126-130
[3]  
DOBBS HS, 1983, TITANIUM ALLOYS SURG, P173
[4]  
LAING PATRICK G., 1967, J BIOMED MAT RES, V1, P135, DOI 10.1002/jbm.820010113
[5]   SENSITIVITY TO TITANIUM - A CAUSE OF IMPLANT FAILURE [J].
LALOR, PA ;
REVELL, PA ;
GRAY, AB ;
WRIGHT, S ;
RAILTON, GT ;
FREEMAN, MAR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01) :25-28
[6]   TITANIUM, A METAL FOR SURGERY [J].
LEVENTHAL, GS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1951, 33-A (02) :473-474
[7]   ASEPTIC LOOSENING IN TOTAL HIP-ARTHROPLASTY SECONDARY TO OSTEOLYSIS INDUCED BY WEAR DEBRIS FROM TITANIUM-ALLOY MODULAR FEMORAL HEADS [J].
LOMBARDI, AV ;
MALLORY, TH ;
VAUGHN, BK ;
DROUILLARD, P .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (09) :1337-1342
[8]   FRICTION AND WEAR PROPERTIES OF POLYMER, METAL, AND CERAMIC PROSTHETIC JOINT MATERIALS EVALUATED ON A MULTICHANNEL SCREENING DEVICE [J].
MCKELLOP, H ;
CLARKE, I ;
MARKOLF, K ;
AMSTUTZ, H .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1981, 15 (05) :619-653
[9]  
MCKELLOP H, 1988, ACTA ORTHOP SCAND, V59, P349
[10]   THE WEAR BEHAVIOR OF ION-IMPLANTED TI-6AL-4V AGAINST UHMW POLYETHYLENE [J].
MCKELLOP, HA ;
ROSTLUND, TV .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (11) :1413-1425