Improved control of dynamic voltage restorer for compensation of unbalanced and harmonic-distorted grid voltage

被引:0
|
作者
Zhang, Runtao [1 ]
Hu, Xuekai [1 ]
Meng, Liang [1 ]
Zhou, Wen [1 ]
Luo, Peng [1 ]
Li, Zifan [1 ]
机构
[1] State Grid Hebei Elect Power Co Ltd, Elect Power Res Inst, Shijiazhuang 050021, Peoples R China
关键词
Doubly fed induction generator (DFIG); Dynamic voltage restorer (DVR); Harmonics; Voltage unbalance; Power quality;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Doubly fed induction generator (DFIG) are vulnerable to unbalanced voltage and harmonic distortion, which will lead to the heating problem of stator/rotor windings and the damage of gearbox. This paper establishes the transient modeling of the DFIG under composite unbalanced voltage and harmonic distortion condition, and elaborates the dynamic response of DFIG from the perspectives of rotor voltage, active power and reactive power under voltage harmonics and unbalance. It also presents an improved control strategy for a dynamic voltage restorer (DVR) to accurately track the specific voltage harmonics, with targeted consideration of constraining unbalanced voltage and fifth-and seventh-order voltage harmonics. The extractions of each voltage signals are presented in this paper via multiple notch filter (MNF), which has a good low-pass characteristic and an excellent performance in trapping the specific AC signals. The presented notch-filter-based algorithm has the advantages of simper control structure and faster response speed, and is more accurate in harmonic extraction. A 1.5-MW DFIG has been employed to establish the object of protection in simulation analysis to verify the validity of the proposed control strategy. The results show that the proposed control strategy is effective which is consistent with the theoretical model, and the oscillations of each crucial parameter can be well-suppressed. (c) 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1803 / 1811
页数:9
相关论文
共 50 条
  • [21] Design of a capacitor-supported dynamic voltage restorer (DVR) for unbalanced and distorted loads
    Ghosh, A
    Jindal, AK
    Joshi, A
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) : 405 - 413
  • [22] Sliding mode control based dynamic voltage restorer for voltage sag compensation
    Abdelaal, Ashraf K.
    Shaheen, Abdullah M.
    El-Fergany, Attia A.
    Alqahtani, Mohammed H.
    RESULTS IN ENGINEERING, 2024, 24
  • [23] Voltage Swell Compensation in an Interline Dynamic Voltage Restorer
    Rani, P. Usha
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2014, 73 (01): : 29 - 32
  • [24] Boundary control of dynamic voltage restorers in voltage harmonic compensation
    Chan, Paul K. W.
    Chung, Henry S. H.
    Hui, S. Y. R.
    2006 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-7, 2006, : 2855 - +
  • [25] Dynamic Modeling and Improved Control of DFIG Under Distorted Grid Voltage Conditions
    Hu, Jiabing
    Nian, Heng
    Xu, Hailiang
    He, Yikang
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (01) : 163 - 175
  • [26] DYNAMIC VOLTAGE RESTORER AS A SAG MITIGATOR AND HARMONIC RESTORER
    Chandrasekaran, K.
    Venkatachalam, P. A.
    Karsiti, Mohd Noh
    2008 IEEE INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY TECHNOLOGIES (ICSET), VOLS 1 AND 2, 2008, : 904 - 909
  • [27] Control Method of Electrolytic Capacitorless Dual Inverter for Harmonic Compensation Under Distorted Grid Voltage
    Ohno, Yuuki
    Haga, Hitoshi
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (01) : 375 - 387
  • [29] Stationary Frame Control Strategy for Voltage Source Inverter under unbalanced and distorted grid voltage
    Song, Yipeng
    Nian, Heng
    2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 1167 - 1173
  • [30] An Enhanced Voltage Sag Compensation Scheme for Dynamic Voltage Restorer
    Rauf, Abdul Mannan
    Khadkikar, Vinod
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (05) : 2683 - 2692