Current automated fluorescent instruments are all based on slab gels that are used once and then discarded. Practitioners of capillary gel electrophoresis often reuse their gels for multiple samples. As slab gels are made thinner to increase speed, the ability to reload new samples after each run will become more desirable. Techniques have previously been developed for reloading and stabilizing capillary gels. The application of these methods to slab gel electrophoresis is reported. Gels are shown to be reusable for at least four consecutive automated runs. The stability of various slab gel formulations and their ability to survive multiple loadings with sequencing samples are compared. Formamide-containing gels are shown to be superior to their urea counterparts. The potenltial that running buffer additives have for improving automated DNA sequencing is discussed. Residual template DNA in sequencing samples can produce gel instability reduce resolution and decrease signal. These effects are examined.
引用
收藏
页码:684 / &
相关论文
共 50 条
  • [1] STABILITY OF CAPILLARY GELS FOR AUTOMATED SEQUENCING OF DNA
    SWERDLOW, H
    DEWJAGER, KE
    BRADY, K
    GREY, R
    DOVICHI, NJ
    GESTELAND, R
    ELECTROPHORESIS, 1992, 13 (08) : 475 - 483
  • [2] OPTIMIZED SEQUENCING PRIMERS FOR AUTOMATED DNA-SEQUENCING
    PERRY, J
    LENNON, G
    FASEB JOURNAL, 1994, 8 (07): : A1362 - A1362
  • [3] EASY-READ DNA-SEQUENCING GELS
    NELSON, JE
    KRAWETZ, SA
    BIOTECHNIQUES, 1994, 17 (03) : 416 - 418
  • [4] AN IMPROVED METHOD FOR POURING DNA-SEQUENCING GELS
    LAW, JC
    FERRELL, RE
    BIOTECHNIQUES, 1994, 17 (05) : 850 - 850
  • [5] AUTOMATED DNA-SEQUENCING - A LOOK INTO THE FUTURE
    SMITH, LM
    CANCER DETECTION AND PREVENTION, 1993, 17 (02): : 283 - 288
  • [6] High-speed automated DNA sequencing in ultrathin slab gels
    Smith, LM
    Brumley, RL
    Buxton, EC
    Giddings, M
    Marchbanks, M
    Tong, XC
    HIGH RESOLUTION SEPARATION AND ANALYSIS OF BIOLOGICAL MACROMOLECULES, PT B, 1996, 271 : 219 - 237
  • [7] HIGH-SPEED AUTOMATED DNA SEQUENCING IN ULTRATHIN SLAB GELS
    KOSTICHKA, AJ
    MARCHBANKS, ML
    BRUMLEY, RL
    DROSSMAN, H
    SMITH, LM
    BIO-TECHNOLOGY, 1992, 10 (01): : 78 - 81
  • [8] DNA-SEQUENCING - MODULAR PRIMERS FOR AUTOMATED WALKING
    KOTLER, L
    SOBOLEV, I
    ULANOVSKY, L
    BIOTECHNIQUES, 1994, 17 (03) : 554 - &
  • [9] ACCURACY OF AUTOMATED DNA-SEQUENCING - A MULTILABORATORY COMPARISON OF SEQUENCING RESULTS
    NAEVE, CW
    BUCK, GA
    NIECE, RL
    PON, RT
    ROBERTSON, M
    SMITH, AJ
    BIOTECHNIQUES, 1995, 19 (03) : 448 - 453
  • [10] ACCURACY OF AUTOMATED DNA-SEQUENCING - A MULTILABORATORY COMPARISON OF SEQUENCING RESULTS
    NAEVE, CW
    NIECE, RL
    FASEB JOURNAL, 1995, 9 (06): : A1260 - A1260