Automatic 3D foetal face model extraction from ultrasonography through histogram processing

被引:9
作者
Bonacina, Luca [1 ]
Froio, Antonio [2 ]
Conti, Daniele [3 ]
Marcolin, Federica [4 ]
Vezzetti, Enrico [4 ]
机构
[1] Polytech Univ Milan, Dept Elect Informat & Bioengn, Milan, Italy
[2] Polytech Univ Turin, Dept Energy, Turin, Italy
[3] Polytech Univ Turin, Dept Appl Sci & Technol, Turin, Italy
[4] Polytech Univ Turin, Dept Management Engn & Prod, Cso Duca Abruzzi 24, I-10129 Turin, Italy
关键词
3D histogram processing; 3D ultrasound; DICOM; Image segmentation;
D O I
10.1016/j.jmu.2016.08.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Ultrasound is by far the most adopted method for safe screening and diagnosis in the prenatal phase, thanks to its non-harmful nature with respect to radiation-based imaging techniques. The main drawback of ultrasound imaging is its sensitivity to scattering noise, which makes automatic tissues segmentation a tricky task, limiting the possible range of applications. An algorithm for automatically extracting the facial surface is presented here. The method provides a comprehensive segmentation process and does not require any human intervention or training procedures, leading from the output of the scanner directly to the 3D mesh describing the face. The proposed segmentation technique is based on a two-step statistical process that relies on both volumetric histogram processing and 2D segmentation. The completely unattended nature of such a procedure makes it possible to rapidly populate a large database of 3D point clouds describing healthy and unhealthy faces, enhancing the diagnosis of rare syndromes through statistical analyses. (C) 2016, Elsevier Taiwan LLC and the Chinese Taipei Society of Ultrasound in Medicine. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:142 / 149
页数:8
相关论文
共 26 条
[1]   Automatic Segmentation of Antenatal 3-D Ultrasound Images [J].
Anquez, Jeremie ;
Angelini, Elsa D. ;
Grange, Gilles ;
Bloch, Isabelle .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (05) :1388-1400
[2]  
Bourke P., 2007, PLY POLYGON FILE FOR
[3]  
Cignoni P., 2008, ERCIM NEWS, V73, P45, DOI DOI 10.2312/L0CALCHAPTEREVENTS/ITALCHAP/ITALIANCHAPC0NF2008/129-136
[4]  
Conti D, ARTIF INTEL IN PRESS
[5]  
Feng S, COMP VIS PATT REC 20, P2488
[6]   3-D ultrasound imaging: A review [J].
Fenster, A ;
Downey, DB .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06) :41-51
[7]  
GE, 2014, 4DVIEW
[8]  
Kazhdan M, P 4 EUR S GEOM PROC, V7
[9]   Value of 3D-4D sonography in fetal and gynecological ultrasound examination: principles and indications. [J].
Levaillant, J. M. .
JOURNAL DE RADIOLOGIE, 2006, 87 (12) :1969-1992
[10]  
Li X, P 11 JOINT C INF SCI