SEPARATION OF DRUGS BY PACKED-COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY .1. PHENOTHIAZINE ANTIPSYCHOTICS

被引:44
|
作者
BERGER, TA
WILSON, WH
机构
[1] Hewlett Packard Company, Wilmington, Delaware, 19808
关键词
D O I
10.1002/jps.2600830304
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Studies of speed, resolution, and sensitivity indicate packed column supercritical fluid chromatography is a viable technique for the analysis of antipsychotic drugs. Fourteen such drugs (mostly phenothiazines) were studied from a cyanopropyl liquid chromatography packed column with a tertiary mobile phase of carbon dioxide, methanol, and isopropylamine. An arbitrary mix of 10 components was baseline resolved in similar to 11 min. Detection limits were as low as 125 ppb, with a feasible 10-fold decrease. Without the Isopropylamine in the mobile phase, none of the solutes eluted. With the additive, all produced symmetrical peaks and high efficiency (i.e., >80% of theoretical). Changing modifier concentration was the most effective physical parameter for changing retention but had little effect on selectivity. Temperature changes had a modest effect an retention but provided surprisingly large changes in selectivity, with numerous peak reversals occurring over only a 30 degrees C temperature range. In addition, temperature programming was the most effective means to optimize resolution of the 10-component mix. No noticeable loss in efficiency accompanied the temperature programs.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 50 条
  • [31] DETERMINATION OF CHLORINATED PESTICIDES BY PACKED-COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY ELECTRON-CAPTURE DETECTOR
    YARITA, T
    NOMURA, A
    HORIMOTO, Y
    YAMADA, J
    MICROCHEMICAL JOURNAL, 1994, 49 (2-3) : 145 - 149
  • [32] SELECTIVITY TRENDS IN PACKED-COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY WITH C-18 STATIONARY PHASES
    WILLIAMS, KL
    SANDER, LC
    PAGE, SH
    WISE, SA
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1995, 18 (08): : 477 - 482
  • [33] PACKED-COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY COUPLED WITH ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    SADOUN, F
    VIRELIZIER, H
    ARPINO, PJ
    JOURNAL OF CHROMATOGRAPHY, 1993, 647 (02): : 351 - 359
  • [34] WATER AS A STATIONARY PHASE MODIFIER IN PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY .1. SEPARATION OF FREE FATTY-ACIDS
    GEISER, FO
    YOCKLOVICH, SG
    LURCOTT, SM
    GUTHRIE, JW
    LEVY, EJ
    JOURNAL OF CHROMATOGRAPHY, 1988, 459 : 173 - 181
  • [35] Clinical and pharmaceutical applications of packed-column supercritical fluid chromatography
    Abbott, Eric
    Veenstra, Timothy D.
    Issaq, Haleem J.
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (08) : 1223 - 1230
  • [36] Peak compression effects in packed-column supercritical fluid chromatography
    Strode, JT
    Gyllenhaal, O
    Torstensson, A
    Karlsson, A
    Karlsson, L
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1998, 36 (05) : 257 - 262
  • [37] ANALYSIS OF FELODIPINE BY PACKED-COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY WITH ELECTRON-CAPTURE AND ULTRAVIOLET ABSORBENCY DETECTION
    STRODE, JTB
    TAYLOR, LT
    HOWARD, AL
    IP, D
    BROOKS, MA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (08) : 1003 - 1014
  • [38] COMPARISON OF STATIONARY PHASES FOR PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY
    SCHOENMAKERS, PJ
    UUNK, LGM
    JANSSEN, HG
    JOURNAL OF CHROMATOGRAPHY, 1990, 506 : 563 - 578
  • [39] USE OF THE PHOTOIONISATION DETECTOR IN PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY
    SIM, PG
    ELSON, CM
    QUILLIAM, MA
    JOURNAL OF CHROMATOGRAPHY, 1988, 445 (01): : 239 - 243
  • [40] APPLICATION OF PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY TO THE ANALYSIS OF BARBITURATES
    SMITH, RM
    SANAGI, MM
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1988, 6 (6-8) : 837 - 841