共 3 条
A RAPID METHOD FOR MEASURING SERUM AMYLOID-A PROTEIN BY LATEX AGGLUTINATION NEPHELOMETRIC IMMUNOASSAY
被引:39
|作者:
YAMADA, T
[1
]
NOMATA, Y
[1
]
SUGITA, O
[1
]
OKADA, M
[1
]
机构:
[1] EIKEN CHEM CO LTD,TOKYO RES LAB,KATSUSHIKA KU,TOKYO 124,JAPAN
关键词:
KINETIC ASSAY;
ACUTE PHASE REACTANT;
HIGH DENSITY LIPOPROTEIN;
D O I:
10.1177/000456329303000112
中图分类号:
R446 [实验室诊断];
R-33 [实验医学、医学实验];
学科分类号:
1001 ;
摘要:
Serum amyloid A protein (SAA) is a sensitive acute phase reactant. We developed a method for the rapid measurement of human SAA in serum by kinetic nephelometry of anti-SAA antibody-coated latex agglutination. Measurement takes less than 6 min using an automated analyser. Standardization of the assay employs SAA-enriched high density lipoprotein as the primary standard. The values determined by our new method and by conventional enzymeimmunoassay showed good agreement (r = 0.988). The normal range was 0.17 - 10.0 mg/L [mean (SD)]. This rapid method should prove useful in clinical laboratories.