DETECTION OF CANINE INTERLEUKIN-2 RECEPTORS BY FLOW-CYTOMETRY

被引:21
|
作者
SOMBERG, RL [1 ]
ROBINSON, JP [1 ]
FELSBURG, PJ [1 ]
机构
[1] PURDUE UNIV,SCH VET MED,DEPT VET PHYSIOL & PHARMACOL,W LAFAYETTE,IN 47907
关键词
D O I
10.1016/0165-2427(92)90031-K
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
This study describes a method for detecting canine interleukin-2 receptors (IL-2R) by flow cytometry, using human recombinant IL-2 labeled with phycoerythrin (IL-2-PE). Peripheral blood mononuclear cells from four normal dogs were washed, incubated with IL-2-PE, and then washed to remove any unbound IL-2-PE. Flow cytometric analysis of the cells was performed with a 488 nm argon laser while gating on lymphocytes. Cells expressing the IL-2R were identified by their fluorescence as compared to cells stained with an anti-mouse immunoglobulin-G conjugated to phycoerythrin. The average percentage of resting cells expressing the IL-2R was found to be 21%. The addition of unlabeled human recombinant IL-2 to Day 3 phytohemagglutinin (PHA)-stimulated cells reduced the fluorescence intensity four-fold, thereby demonstrating the specificity of IL-2-PE for canine IL-2R. Following stimulation with optimal concentrations of PHA, the percentage of cells expressing the IL-2R increased daily and reached a maximum on Day 3 (76.4%). IL-2R density, as measured by mean fluorescence intensity, also increased and reached maximal levels on Days 2-3 (twenty-fold greater than resting cells). The binding, inhibition, and kinetic experiments provide evidence that human recombinant IL-2-PE is a useful tool for studying canine IL-2R expression. Thus, a one-step direct method for the flow cytometric detection and quantification of the canine IL-2R is now available.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 50 条
  • [41] A novel multicolor flow-cytometry application for quantitative detection of receptors on vascular smooth muscle cells
    Radziwon-Balicka, Aneta
    Degn, Matilda
    Johansson, Sara E.
    Warfvinge, Karin
    Edvinsson, Lars
    PLOS ONE, 2017, 12 (10):
  • [42] RETICULOCYTE COUNTS IN CANINE AND RAT-BLOOD MADE BY FLOW-CYTOMETRY
    EVANS, GO
    FAGG, R
    JOURNAL OF COMPARATIVE PATHOLOGY, 1994, 111 (01) : 107 - 111
  • [43] FLOW-CYTOMETRY OF SPERM
    GLEDHILL, BL
    HUMAN REPRODUCTION /: CURRENT STATUS / FUTURE PROSPECT, 1988, 768 : 363 - 369
  • [44] APPLICATION OF FLOW-CYTOMETRY TO THE DETECTION OF SPINDLE POISONS AND CLASTOGENS
    MAIER, P
    SCHAWALDER, HP
    FOOD AND CHEMICAL TOXICOLOGY, 1986, 24 (6-7) : 702 - 702
  • [45] DETECTION OF MESSENGER-RNA SPECIES BY FLOW-CYTOMETRY
    BELLOC, F
    DURRIEU, F
    METHODS IN CELL BIOLOGY, VOL 42, 1994, 42 : 59 - 69
  • [46] FLOW-CYTOMETRY DETECTION AND EVALUATION OF BLADDER-TUMORS
    MELAMED, MR
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1990, 32 (09) : 829 - 833
  • [47] RAPID DETECTION OF ANTIMICROBIAL ACTIVITY USING FLOW-CYTOMETRY
    DURODIE, J
    COLEMAN, K
    SIMPSON, IN
    LOUGHBOROUGH, SH
    WINSTANLEY, DW
    CYTOMETRY, 1995, 21 (04): : 374 - 377
  • [48] SENSITIVE DETECTION OF RNAS IN SINGLE CELLS BY FLOW-CYTOMETRY
    YU, H
    ERNST, L
    WAGNER, M
    WAGGONER, A
    NUCLEIC ACIDS RESEARCH, 1992, 20 (01) : 83 - 88
  • [49] DETECTION OF BORRELIACIDAL ANTIBODIES IN HAMSTERS BY USING FLOW-CYTOMETRY
    SACHSENMEIER, KF
    SCHELL, K
    MORRISSEY, LW
    PENNELL, DR
    WEST, RM
    CALLISTER, SM
    SCHELL, RF
    JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (06) : 1457 - 1461
  • [50] APPLICATION OF FLOW-CYTOMETRY TO DETECTION AND CHARACTERIZATION OF LEGIONELLA SPP
    TYNDALL, RL
    HAND, RE
    MANN, RC
    EVANS, C
    JERNIGAN, R
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1985, 49 (04) : 852 - 857