DETECTION OF CANINE INTERLEUKIN-2 RECEPTORS BY FLOW-CYTOMETRY

被引:21
|
作者
SOMBERG, RL [1 ]
ROBINSON, JP [1 ]
FELSBURG, PJ [1 ]
机构
[1] PURDUE UNIV,SCH VET MED,DEPT VET PHYSIOL & PHARMACOL,W LAFAYETTE,IN 47907
关键词
D O I
10.1016/0165-2427(92)90031-K
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
This study describes a method for detecting canine interleukin-2 receptors (IL-2R) by flow cytometry, using human recombinant IL-2 labeled with phycoerythrin (IL-2-PE). Peripheral blood mononuclear cells from four normal dogs were washed, incubated with IL-2-PE, and then washed to remove any unbound IL-2-PE. Flow cytometric analysis of the cells was performed with a 488 nm argon laser while gating on lymphocytes. Cells expressing the IL-2R were identified by their fluorescence as compared to cells stained with an anti-mouse immunoglobulin-G conjugated to phycoerythrin. The average percentage of resting cells expressing the IL-2R was found to be 21%. The addition of unlabeled human recombinant IL-2 to Day 3 phytohemagglutinin (PHA)-stimulated cells reduced the fluorescence intensity four-fold, thereby demonstrating the specificity of IL-2-PE for canine IL-2R. Following stimulation with optimal concentrations of PHA, the percentage of cells expressing the IL-2R increased daily and reached a maximum on Day 3 (76.4%). IL-2R density, as measured by mean fluorescence intensity, also increased and reached maximal levels on Days 2-3 (twenty-fold greater than resting cells). The binding, inhibition, and kinetic experiments provide evidence that human recombinant IL-2-PE is a useful tool for studying canine IL-2R expression. Thus, a one-step direct method for the flow cytometric detection and quantification of the canine IL-2R is now available.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 50 条
  • [11] DETECTION OF INTRACYTOPLASMIC ANTIGENS BY FLOW-CYTOMETRY
    SCHROFF, RW
    BUCANA, CD
    KLEIN, RA
    FARRELL, MM
    MORGAN, AC
    JOURNAL OF IMMUNOLOGICAL METHODS, 1984, 70 (02) : 167 - 177
  • [12] DETECTION OF ANTIPHOSPHOLIPID ANTIBODIES BY FLOW-CYTOMETRY
    STEWART, MW
    ETCHES, WS
    GORDON, PA
    THROMBOSIS AND HAEMOSTASIS, 1991, 65 (06) : 1000 - 1000
  • [13] DETECTION OF GRANULOCYTE ANTIBODIES BY FLOW-CYTOMETRY
    MADYASTHA, P
    GLASSMAN, AB
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 1987, 17 (04): : 267 - 268
  • [14] THE DETECTION OF PLATELET ALLOANTIBODIES BY FLOW-CYTOMETRY
    WORFOLK, LA
    MACPHERSON, BR
    TRANSFUSION, 1991, 31 (04) : 340 - 344
  • [15] DETECTION OF PLATELET AUTOANTIBODIES BY FLOW-CYTOMETRY
    MACEY, MG
    MORRIS, A
    HYAM, C
    SANGSTER, J
    NEWLAND, AC
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1990, (98): : 841 - 844
  • [16] DETECTION OF INTRACELLULAR CYTOKINES BY FLOW-CYTOMETRY
    JUNG, T
    SCHAUER, U
    HEUSSER, C
    NEUMANN, C
    RIEGER, C
    JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 159 (1-2) : 197 - 207
  • [17] DETECTION OF INTRACYTOPLASMIC IMMUNOGLOBULINS BY FLOW-CYTOMETRY
    FILIPPI, JF
    TUBIANA, N
    LECAER, F
    SAMPOL, J
    CARCASSONNE, Y
    NOUVELLE REVUE FRANCAISE D HEMATOLOGIE, 1986, 28 (05): : 297 - 302
  • [18] INTERLEUKIN-2 RECEPTORS
    ALLOUCHE, M
    SAHRAOUI, Y
    AUGERYBOURGET, Y
    PERRAKIS, M
    JASMIN, C
    GEORGOULIAS, V
    LEUKEMIA RESEARCH, 1990, 14 (08) : 699 - 703
  • [19] REGULATION BY INTERLEUKIN-2 OF INTERLEUKIN-2 RECEPTORS AND GAMMA-INTERFERON SYNTHESIS BY HUMAN THYMOCYTES - AUGMENTATION OF INTERLEUKIN-2 RECEPTORS BY INTERLEUKIN-2
    REEM, GH
    YEH, NH
    JOURNAL OF IMMUNOLOGY, 1985, 134 (02): : 953 - 958
  • [20] CORTICOSTEROID INTERLEUKIN-2 INTERACTIONS - INHIBITION OF BINDING OF INTERLEUKIN-2 TO INTERLEUKIN-2 RECEPTORS
    HORST, HJ
    FLAD, HD
    CLINICAL AND EXPERIMENTAL IMMUNOLOGY, 1987, 68 (01): : 156 - 161